Page 1
Mobile reader SIMATIC RF660M Introduction Safety instructions SIMATIC Ident Description Commissioning RFID systems Mobile reader SIMATIC RF660M "SIMATIC Mobile Reader" Maintenance and service Operating Instructions Technical specifications Appendix Service & Support 02/2022 C79000-G8976-C660-01...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
"Tag Editor" menu ......................40 5.4.3 "Locate" menu ........................48 "Settings" menu ......................... 50 Maintenance and service ........................59 Cleaning and maintenance....................59 App update and installations ....................59 MCon update ........................61 Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 4
Technical specifications of the UHF head module SIMATIC RF660H ........65 Technical specifications of the charging/docking station ............. 66 Appendix ............................. 67 Encryption methods (ciphers) .................... 67 Certificates & approvals ..................... 68 Order data ......................... 69 Service & Support ..........................71 Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
You can find detailed information on the transponders that can be read with SIMATIC RF160B in the "SIMATIC RF600" system manuals. You will find the current version of the manual on the pages of the Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/14971/man).
Page 6
Do not dispose of the products at public disposal sites. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste or your Siemens representative. Note the different country-specific regulations.
To operate the mobile reader and the docking station, only original power supply units that can be ordered from Siemens and batteries approved by Siemens may be used! The use of impermissible components can result in the destruction of the mobile reader or the docking station.
• The device does not have user management functions. Make sure that only adequately qualified and authorized personnel have access to the device. • Lock unused physical ports (e.g. Ethernet ports) on the device. Unused ports can be used to access the system without authorization. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 9
• Keep the software up to date. Keep yourself informed regularly about safety updates for the product. You can find information about this at Link: (https://www.siemens.com/industrialsecurity). • Make sure that the apps installed and operated on the device are from trusted sources.
You can find more information on the encryption methods used in the appendix. If the application was started. Explanation of the table: • Authentication Specifies whether authentication of the communication partner takes place. • Encryption Specifies whether the transfer is encrypted. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to...
Page 12
Safety instructions 2.4 Security information Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Description The SIMATIC RF660M mobile reader consists of a SIMATIC RF160B basic device and a head module. In conjunction with the SIMATIC RF660H UHF head module, the reader can be used in the UHF area (SIMATIC RF600). Area of application SIMATIC RF660M expands the RFID systems with a powerful mobile UHF reader for applications in the areas of logistics, production and service.
Page 14
• Display and edit data in decimal, hexadecimal and ASCII format • Password protection of the transponder that can be enabled or disabled • Logbook function • App in English and German Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 15
400 kbps speed Readable • ISO 18000-62 transponder standards • ISO 18000-63 • EPCglobal UHF Class 1 Gen 2 Depending on the country or region and the SIMATIC RF660H head module version used Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
3. Insert the DC plug of the power supply unit into the DC socket on the rear of the charging/docking station ( 4. If necessary, insert the Ethernet cable into the RJ45 socket on the rear of the charging/docking station. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
"Attaching/replacing the reader handle (Page 25)". 2. Turn or lay the reader on its front. 3. Open the battery compartment by pressing the latch (metal clip) lengthways towards the head module (top of reader) ①. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 19
In battery replacement during operation, the display is disabled for energy-saving reasons. All other device functions, in particular the processor, memory and WLAN, remain operational. In addition, the device clock continues counting time for several days even without battery. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
①. 2. Then press the spare battery downwards ②. Make sure that the spare battery latches into place. Figure 4-5 Inserting the battery in the charging/docking station Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 21
Reader battery (Speed CHARGE) The reader battery is being charged. Green The reader battery is fully charged. Spare battery (CHARGE) The spare battery is being charged. Green The spare battery is fully charged. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Temperature rise during continuous operation Please note that the UHF module can get very warm during continuous operation. To protect persons and the module, the maximum duration of a read operation is limited to two minutes. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 23
Procedure You can easily replace the head module interface cover or the head module by sliding it off or onto the base module from the side. Figure 4-8 Replacing the head module Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
1. Turn or lay the reader on its front. 2. Push or pull the retaining strap upwards from the bottom through the upper retaining strap hook. Figure 4-9 Pushing/pulling the retaining strap through Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
The pistol handle does not impede replacing the head module or charging the mobile reader. Both are possible with the pistol handle. However, the pistol handle must be removed before replacing the battery. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
There is a 5 MP autofocus camera with flash/lighting on the rear of the mobile reader. Using this camera and the corresponding software (app for reading codes), you can optionally also use the reader to read bar codes and 2D codes. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Idle mode and this mode can therefore only be retained for a certain amount of time (depending on the charge level of the reader battery). To switch back to operational mode, press the On/Off button on he right of the reader again ( ). Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Scanner On the right and left of the Gray button Start scan/read operation button (2x) reader. The antenna field of the reader is scanned and data is read from the detected transponders. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Android contains a Linux kernel, but is not a traditional Linux distribution as known for desktops and servers. Some basic properties that you would expect in a UNIX family system have been changed significantly. Nevertheless, many properties are comparable to other embedded Linux distributions. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 30
DHCP by default. To integrate the charging/docking station into a network, you need to create the "network_settings.ini" file under the path "sdcard > ACD". The file must contain the following entries: Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 31
Android as standard. You can edit these parameters in the file "wifi_config.conf" ("sdcard > ACD > wifi"). The values are also described in detail there. To apply the specific WLAN settings, you need to enter the maintenance code "77696" in the SystemApp. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 32
Commissioning 4.2 Commissioning and operation (software) Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
• Arrow symbol (left): Back button • Circle symbol (center): Button to return to the home screen • Square symbol (right): Button to open the apps that are still active in the background. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
This information serves the purpose of unique transponder identification. • USER A freely usable memory area that can be written with user-defined data. This memory area is optional and is not present with all transponder types. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 35
'destroy' the transponder. You can find detailed information on changing the passwords and locking memory areas using the Access password in the section ""Tag Editor" menu (Page 40)". Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Using the menu, you can scan for transponders, edit and locate them. In the menu "Settings" , you can configure the "SIMATIC Mobile Reader for RFID" app. Figure 5-2 "Home page" menu Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 37
Note that the term "Tag" is used in the "SIMATIC Mobile Reader for RFID" app, whereas the term "Transponder" is used in this manual. These terms are synonyms and have the same meaning. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Figure 5-3 "Scan" menu This menu is split up into two areas. A list of the detected transponders is shown in the upper area. In the bottom area, you can perform scans. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 39
Note that the logbook is created as ring buffer. Note: This function corresponds to the "Scan logbook > Activate" parameter in the "Settings > Logbook" menu. Clear Button to delete all transponders entered in the transponder list. transponder list Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
You can lock memory areas, assign Access and Kill passwords, and 'kill' the transponder. This menu is divided into the following tabs: • Target • Write • Read • Disable Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 41
) and select a target transponder from the transponder list. Note that, by default, the top transponder is always selected. All the functions/settings described in the following tabs only affect the target transponder selected here. Figure 5-4 "Tag Editor > Target" menu Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 42
"SIMATIC Mobile Reader" app 5.4 Functions Write In the "Write" tab, you can change data of a memory area and write it to the target transponder. Figure 5-5 "Tag Editor > Write" menu Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 43
If more data is entered than specified in the "Length (bytes)" box, it is highlighted in color. In this case, the data cannot be written. Write Button to execute the write operation Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 44
"SIMATIC Mobile Reader" app 5.4 Functions Read In the "Read" tab, you can read data from a target transponder. Figure 5-6 "Tag Editor > Read" menu Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 45
Tag data of the Output field showing the data or text that you read out from the selected selected memory area of the target transponder. memory bank Read Button to execute the read operation. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 46
Clicking the button opens a new window in which you can change the respective password. In the drop-down list, select which password you want to change and enter the old password and the new password in the input boxes. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 47
Result: The selected memory area is locked or unlocked. The procedure to 'destroy' is identical, except that you need to enter the Kill password that the complete transponder is destroyed, not just an individual memory area. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
("Update" button ) and select a target transponder from the transponder list. In the lower area, you can define the conditions for the localization operation and start and stop the operation. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 49
Based on the displayed signal strength, you can "work your way" to the selected target transponder and locate it. Note: The localization operation is automatically stopped after 118 seconds to avoid overheating of the head module. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
In the menu "Settings", you can configure the "SIMATIC Mobile Reader for RFID" app. This menu is divided into the following tabs: • Radio • Logbook • Update • Other • Info Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 51
Drop-down list to select the country profile valid for your region or country. The selection depends on the inserted head module. Radiated Drop-down list to select the desired radiated power with which the reader scans power [mW] are performed. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 52
The functions of the search modes "2 (Single target: A to B)" and "3 (Single target: B to A)" are very complex and it is recommended that only trained users should use them. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 53
"SIMATIC Mobile Reader" app 5.5 "Settings" menu Logbook In the "Logbook" tab, you can enable/disable functions, export the logbook and reset it. Figure 5-10 "Settings > Logbook" menu Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 54
You may need to show the internal memory first using the button 3. If necessary, change the file name. 4. At the bottom right, right the "SAVE" button or the icon. Result: The logbook file is saved on the USB stick. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 55
In the "Update" tab, you can update the software (Mcon) of the head module. Figure 5-11 "Settings > Update" menu You can find detailed information on the update in the section "MCon update (Page 61)". Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 56
If the function has been enabled, the distance to the transponder is reproduced by signal sounds when transponders are located. The nearer you get to the transponder, the higher the frequency of the signal sound becomes. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 57
To delete this data, you need to reset the operating system or delete the data manually. You can reset the operating system in the system settings under "Settings > System > Advanced > Reset options > Delete all data (factory settings)". Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 58
The Mask Designer ID contains information on the different transponder types (chip model and chip manufacturer). Based on the MDID, the reader can assign this information to the detected transponders. UHF country Detailed information on the UHF country profile used profile Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
App update and installations You can update the app of the mobile reader using an update file and a USB stick. You can find a current version of the update file on the Siemens Industry Online Support pages (https://support.industry.siemens.com/cs/ww/en/ps/14971/dl). Mobile reader SIMATIC RF660M...
Page 60
Result: The installation is carried out. As soon as it has been completed successfully, a confirmation appears in the dialog window ("App has been installed."). Finally, click the "Finished" button and close the Total Commander. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Using an update file and a USB stick, you can update the interface software of the head module (Module Controller or MCon). You can find a current version of the update file on the Siemens Industry Online Support pages. Requirements •...
Page 62
Maintenance and service 6.3 MCon update Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
3 status LEDs Touch screen Capacitive touch, surface hardness according to MOHS category 5-6 Keyboard • Side on/off button • Two side scanner buttons Camera 5 MP autofocus camera with lighting Sound Integrated loudspeaker Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Page 64
Use at down to -20 °C / -4 °F in cold stores or outdoors is permissible. Provided the device was in operation for at least 20 minutes beforehand. Avoid condensation on the device. Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Color Black Permitted ambient conditions Ambient temperature • During operation • -20 to +50 °C • During transport and storage • -20 to +60 °C Relative humidity 5 to 90%, no condensation Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
Black Permitted ambient conditions Ambient temperature • During operation • 0 to +40 °C • During transport and storage • -20 to +60 °C • During charging • +5 to +35 °C Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...
GNU General Public License. If necessary, you can request the source code of these software components from Siemens AG if you make a request to Siemens Support within three years after sale of the product by Siemens AG. Any costs that will be incurred for necessary workload will be communicated to you when you make the request.
Industry Online Support In addition to the product documentation, you are supported by the comprehensive online information platform of Siemens Industry Online Support at the following Internet address: Link: (https://support.industry.siemens.com/cs/de/en/) Apart from news, you will also find the following there: •...
Page 72
Service & Support Mobile reader SIMATIC RF660M Operating Instructions, 02/2022, C79000-G8976-C660-01...