Degree of protection according to EN 60529
Shock-resistant acc. to EN 60721-3-7, Class 7M2
Vibration-resistant acc. to EN 60721-3-7, Class
7M2
Torsion and bending load
Design, dimensions and weight
Dimensions (Ø x H)
Weight
Type of mounting
Standards, specifications, approvals
MTBF
The values for shock and vibration are maximum values and must not be applied continuously.
1)
2)
The processing instructions of the adhesive manufacturer must be observed.
8.24.5
Dimension drawing
Figure 8-67
All dimensions in mm
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
outside the read/write field
during storage
1)
Dimensional drawing of MDS D522
-40 ... +100 °C
-40 ... +100 °C
IP68
2 hours, 2 bar, +20 °C
500 m/s
1)
2
200 m/s
2
Not permitted
20 x 6 mm
13 g
Glued
2)
1 x transponder thread M20
≤ 1 Nm
285 years
ISO transponder
8.24 MDS D522
6GT2600-5AF00