8.18.4
Technical specifications
Table 8-52
Product type designation
Memory
Memory configuration
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
Mechanical specifications
Enclosure
Recommended distance to metal
Power supply
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
≥ 15 mm
≥ 25 mm
Flush installation of the MDS D124 / D324 / D424 / D524 in metal with spacer
Technical specifications for the MDS D424
UID
User memory
OTP memory
)
g
Material
Color
SIMATIC MDS D424
8 bytes
2000 bytes FRAM
16 bytes FRAM
> 10
12
> 10
12
> 10 years
Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 53)"
Epoxy resin
Black
≥ 15 mm
Inductive, without battery
ISO transponder
8.18 MDS D424
6GT2600-4AC00