8.4.5
Technical specifications
Table 8-11
Product type designation
Memory
Memory configuration
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
Mechanical specifications
Enclosure
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
Degree of protection according to EN 60529
Shock-resistant according to EN 60721-3-7 Class
7M3
Vibration-resistant according to EN 60721-3-7
Class 7M3
Torsion and bending load
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
Technical specifications for MDS D124
UID
User memory
OTP memory
)
g
Material
Color
during write/read access
outside the read/write field
during storage
1)
1)
SIMATIC MDS D124
8 bytes
112 bytes EEPROM
16 bytes (EEPROM)
> 10
14
> 10
6
> 10 years
Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 53)"
PPS
Black
≥ 15 mm
Inductive, without battery
-25 ... +140 °C
from +125 ℃: 20% reduction in the limit dis‐
tance
-40 ... +180 °C
at +180 ℃: Tested up to 5000 hours or 3000 cy‐
cles
-40 ... +125 °C
IP68
2 hours, 2 bar, +20 °C
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
1000 m/s
2
200 m/s
2
Not permitted
ISO transponder
8.4 MDS D124
6GT2600-0AC10
311