The states of the PROFINET/Ethernet connections are indicated by the "LK1" LEDs for interface
"X1 P1R" and "LK2" for interface "X1 P2R". The LEDs can adopt the colors green, red or yellow and
the states off , on , flashing :
Table 5-23
Shows the PROFINET/Ethernet states via the PROFINET/Ethernet LED display
LK*
Meaning
No connection is available.
No cable has been connected.
The flash test is performed for reader identification. At the same time, the LEDs of the operation and status LED
display also flash.
LED test while the reader is starting up.
A connection is available.
5.4.7
Ensuring reliable data exchange
Note that the "center point" of the transponder must be in the area of the transmission window
to ensure secure data exchange. You can find additional information on this in the section
"Transmission window and read/write distance (Page 40)".
5.4.8
Metal-free area
The RF360R can be flush-mounted in metal. Allow for a possible reduction in the field data. To
avoid any influence on the field data, the distance "a" should be kept to.
a ≥
Figure 5-15
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
20 mm
Metal-free area for RF360R
Readers
5.4 SIMATIC RF360R