RF300 transponder
7.8 SIMATIC RF380T
7.8.6
Use of the transponder in the Ex protection area
The TÜV SÜD Automotive GmbH as approved test center as well as the TÜV SÜD Product Service
GmbH as certification center, identification number 0123, as per Article 9 of the Directive of the
European Council of 23 March 1994 (94/9/EC), has confirmed the compliance with the essential
health and safety requirements relating to the design and construction of equipment and
protective systems intended for use in hazardous areas as per Annex II of the Directive. The
essential health and safety requirements are satisfied in accordance with the following
standards:
Table 7-20
Document
EN 60079-0: 2006
EN 60079-15: 2005
DIN VDE 0848-5: 2001
(in parts)
ZLS SK 107.1
Identification
Table 7-21
-25°C to +70°C
Um=30Vdc
The equipment is assigned the following references:
XXXYYYZZZ
TPS 09 ATEX 1 459 X
"No use of the equipment in the vicinity of processes generating high charges"
7.8.6.1
Use of the transponder in hazardous areas for gases
Temperature class delineation for gases
The temperature class of the transponder for hazardous areas depends on the ambient
temperature range:
Ambient temperature range
-25 °C to +70 °C
294
Approvals
Title
Electrical equipment for hazardous gas atmospheres -
Part 0: General requirements
Electrical equipment for hazardous gas atmospheres -
Part 15: Design, testing and identification of electrical equipment
with type of protection "n"
Safety in electrical, magnetic and electromagnetic fields -
Part 5: Explosion protection
Central office of the states for safety; test components
The identification of the electrical equipment as an encapsulated unit
II 3G Ex nC IIB T5
[= serial number, is assigned during production]
[= certificate number]
Temperature class
T5