WARNING
WARNING – POTENTIAL ELECTROSTATIC CHARGING HAZARD.
All models must be mounted in an enclosure with a minimum ingress protection rating of
at least IP54 and must be Class I, Zone 2 certified, and used in an environment of not more
than pollution degree 2.
The device may only be operated so that there is adequate protection against ultraviolet light.
The device must not be operated in areas influenced by charge-producing processes.
The device must be set up and installed so that it is mechanically protected.
After disconnecting connections (signal/supply cable), before the connectors are plugged in
again, the connectors must be checked for contamination and, if necessary, cleaned.
5.3.2.8
Technical specifications
Table 5-17
Product type designation
Radio frequencies
Operating frequency, rated value
Electrical data
Output power (antenna input)
Maximum range
•
•
•
•
•
Maximum data transmission speed
reader ↔ transponder
•
•
Transmission speed
Read/write distances of the reader
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
WARNING
Technical specifications of the RF350R reader
ANT 1
ANT 3
ANT 12
ANT 18
ANT 30
Read
Write
SIMATIC RF350R
13.56 MHz
≃ 0.4 W
1)
•
140 mm
•
50 mm
•
16 mm
•
35 mm
•
55 mm
RF300
transponder
•
≤ 8000
bytes/s
•
≤ 8000
bytes/s
19.2, 57.6, 115.2 kBd
See section "Field data for transponders, readers
and antennas (Page 49)"
Readers
5.3 SIMATIC RF340R/RF350R
6GT2801-4BA10
6GT2801-4BA10-0AX2
ISO
ISO transpond‐
transponder
er
(MDS D)
(MDS E)
•
≤ 3300
•
≤ 3400
bytes/s
bytes/s
•
≤ 1700
•
≤ 800
bytes/s
bytes/s
171