ISO transponder
8.4 MDS D124
Design, dimensions and weight
Dimensions (Ø x H)
Weight
Type of mounting
Standards, specifications, approvals
MTBF
The values for shock and vibration are maximum values and must not be applied continuously.
1)
) To prevent it loosening during operation, secure the screw with screw locking varnish.
2
The processing instructions of the adhesive manufacturer must be observed.
3)
8.4.6
EC declaration of conformity according to directive 2014/34/EU MDS D124
The EC type-examination certificate for the MDS D124 transponder was substantiated by TÜV 12
ATEX 084413 X. Based on this certificate, the CE declaration was made by the manufacturer
according to directive 2014/34/EU.
The manufacturing plant of the MDS D124 has an ATEX quality assurance system recognized by
DEKRA EXAM GmbH with notification number "BVS 11 ATEX ZQS/E111".
Manufacturer's address - distributor
Siemens AG
DE – 76181 Karlsruhe, Germany
8.4.7
Dimension drawing
Figure 8-10
All dimensions in mm
312
Dimension drawing of MDS D124
27 x 4 mm
5 g
1 x M3 screw
2)
≤ 1 Nm
Glued
3)
With spacer
228 years
Manufacturer's address - factory
Siemens AG
Würzburger Str. 121
DE - 90766 Fürth, Germany