5.1.9
Technical specifications
Table 5-4
Product type designation
Radio frequencies
Operating frequency, rated value
Electrical data
Output power (antenna input)
Maximum range
Maximum data transmission speed
reader ↔ transponder
Transmission speed
Read/write distances of the reader
Interfaces
Electrical connector design
Standard for interfaces for communication
Antenna
Mechanical specifications
Enclosure
Recommended distance to metal
Supply voltage, current consumption, power loss
Supply voltage
Typical current consumption
Permitted ambient conditions
Ambient temperature
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
Technical specifications of the RF310R reader with RS-422 interface
1)
Read
Write
Material
Color
During operation
During transportation and storage
6GT2801-1BA10
6GT2801-1BA10-0AX2
SIMATIC RF310R
13.56 MHz
≃ 0.3 W
60 mm
RF300
ISO
transponder
transponder
(MDS D)
≤ 8000
≤ 3300
bytes/s
bytes/s
≤ 8000
≤ 1700
bytes/s
bytes/s
19.2, 57.6, 115.2 kBd
See section "Field data for transponders, readers
and antennas (Page 49)"
M12, 8-pin
RS-422
integrated
Plastic PA 12
TI-Grey
Mounting on metal permitted
24 VDC
60 mA
-25 ... +70 °C
-40 ... +85 °C
Readers
5.1 SIMATIC RF310R
ISO transpond‐
er
(MDS E)
≤ 3400
bytes/s
≤ 800
bytes/s
137