b
Figure 6-26
6.6.5
Minimum clearances
Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive fields
will be affected. In this case, the data transmission time can increase unpredictably or a
command is aborted with an error.
For this reason, please observe the values in the tables.
Minimum distances from antenna to antenna
D
Figure 6-27
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
= 10 mm
= 10 mm
ANT 18 flush-mounted in metal
≥ 100 mm
Minimum distance for ANT 18
Antennas