7.4.4
Technical specifications
Table 7-8
Product type designation
Memory
Memory organization
Memory configuration
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
Mechanical specifications
Enclosure
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
Degree of protection according to EN 60529
Shock-resistant according to EN 60721-3-7 Class 7
M2
Vibration-resistant according to EN 60721-3-7
Class 7 M2
Torsion and bending load
Design, dimensions and weight
Dimensions (L x W x H)
Weight
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
Technical specifications for RF340T
UID
User memory
OTP memory
)
g
Material
Color
during write/read access
outside the read/write field
during storage
1)
1)
SIMATIC RF340T
in bytes
4 bytes EEPROM
8 KB FRAM / 32 KB FRAM
20 bytes EEPROM
> 10
10
> 10
10
> 10 years
Dependent on the reader used, see section "Field
data of RF300 transponders (Page 50)"
Plastic PA 12
Anthracite
≥ 0 mm
Inductive, without battery
-25 ... +85 °C
-40 ... +85 °C
-40 ... +85 °C
IP68
IPx9K
500 m/s
2
200 m/s
2
Not permitted
47.5 x 25 x 15.4 mm
25 g
RF300 transponder
7.4 SIMATIC RF340T
6GT2800-4BB00
6GT2800-5BB00
271