Advertisement

ISO transponder
8.28 MDS D526
Flush-mounted in metal
h ≥ 25 mm
a
Figure 8-77
8.28.4
Technical specifications
Table 8-76
Product type designation
Memory
Memory configuration
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
Mechanical specifications
Enclosure
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
404
≥ 50 mm
Flush installation of the MDS D126 / D426 / D526 in metal with spacer
Technical specifications for MDS D526
UID
User memory
)
g
Material
Color
SIMATIC MDS D526
8 bytes
8192 bytes FRAM
> 10
12
> 10
12
> 10 years
Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 53)"
Plastic PA 6.6 GF
Black
≥ 25 mm
Inductive, without battery
System Manual, 02/2021, C79000-G8976-C345-09
6GT2600-5AH00
SIMATIC RF300

Advertisement