Planning the RF300 system
4.3 Installation guidelines
Reader RF350R with ANT 18 and with ISO transponders (MDS D)
Table 4-55
Transponder
MDS D124
MDS D127
MDS D160
MDS D324
MDS D421
MDS D521
MDS D422
MDS D522
MDS D424
MDS D524
MDS D425
MDS D525
MDS D428
MDS D528
MDS D460
MDS D560
1)
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
adequate clearance to the metal.
86
Reduction of field data due to metal, range as %: Transponder and RF350R with ANT 18
Without metal
1)
On metal, distance 15 mm
Flush-mounted in metal;
circumferential distance 25 mm
Without metal
On metal, distance 0 mm
Flush-mounted in metal;
circumferential distance 0 mm
1)
Without metal
On metal, distance 10 mm
Without metal
1)
On metal; distance 15 mm
Flush-mounted in metal;
circumferential distance 25 mm
Without metal
On metal, distance 0 mm
Flush-mounted in metal;
circumferential distance 0 mm
Without metal
On metal, distance 0 mm
Without metal
1)
1)
On metal 15 mm
Flush-mounted in metal;
circumferential distance 25 mm
Without metal
On metal, distance 0 mm
Without metal
On metal, distance 0 mm
Without metal
1)
1)
On metal, distance 15 mm
ANT 18 without metal
100
85
85
100
95
60
100
85
100
90
80
100
90
40
100
95
100
85
75
100
100
100
95
100
95
System Manual, 02/2021, C79000-G8976-C345-09
ANT 18 mounted
in metal
(10 mm all-round)
85
75
45
90
85
60
80
75
80
75
65
85
65
20
85
85
85
80
75
85
85
95
95
95
95