7.2.4
Technical data
Table 7-3
Product type designation
Memory
Memory organization
Memory configuration
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
Mechanical specifications
Enclosure
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
Degree of protection according to EN 60529
Shock-resistant according to EN 60721-3-7 Class 7
M3
Vibration-resistant according to EN 60721-3-7
Class 7 M3
Torsion and bending load
Design, dimensions and weight
Dimensions (Ø x H)
Weight
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
Technical specifications for RF320T
UID
User memory
OTP memory
)
g
Material
Color
during write/read access
outside the read/write field
during storage
1)
1)
SIMATIC RF320T
Byte-oriented, write protection possible in 4-byte
blocks
4 bytes EEPROM
20 bytes EEPROM
20 bytes EEPROM
> 10
14
> 10
5
> 10 years
Dependent on the reader used, see section "Field
data of RF300 transponders (Page 50)"
Epoxy resin
Black
≥ 20 mm
Inductive, without battery
-25 ... +125 °C
-40 ... +140 °C
-40 ... +140 °C
IP67
IPx9K
1000 m/s
2
200 m/s
2
Not permitted
27 x 4 mm
5 g
RF300 transponder
7.2 SIMATIC RF320T
6GT2800-1CA00
263