ISO transponder
8.23 MDS D521
Flush-mounting of the MDS in metal with tools
b
1
d
1
t
1
Figure 8-62
Note
Installation instruction
The MDS should not protrude out of the locating hole; it must be flush with the outside contour.
The mounting instructions of the MDS and the conditions associated with the application (e.g.
peripheral speed, temperature, and use of coolant) must be observed during the installation.
Mounting information for adhesion
• Drill installation hole
• The adhesive surfaces must be dry, free from dust, oil, stripping agents and other impurities
• Apply adhesive according to the manufacturer's processing instructions
• Press in transponder by hand, with antenna side outwards (see figure above)
• Remove residues of adhesive
• Allow to cure according to the manufacturer's instructions
• Flush-mounting of the transponder in metal with tools
Installation examples
Figure 8-63
386
0.5 x 45°
10 (-0.04... -0.13)
4.5 (-0 ... -0.1)
Flush-mounting of MDS D421 / D521 in metal with tools; all dimensions in mm
Installation example of MDS D421/D521/E623 in a steep cone
b
0.3 x 45° or R0.3
2
d
10 (+0.09... 0)
2
t
4.6 (+0.2 ... 0)
2