Use in hazardous areas
TÜV NORD CERT GmbH, appointed center no. 0044 as per Article 18 of the directive of the
European Council of 26 February 2014 (2014/34/EU), has confirmed the compliance with the
essential health and safety requirements relating to the design and construction of equipment
and protective systems intended for use in hazardous areas as per Annex II of the directive.
The essential health and safety requirements are satisfied in accordance with standards EN IEC
60079-0:2018 and EN 60079-11:2012.
This allows the transponder to be used in hazardous areas for gases, for the device category 1G
and gas group IIC, or alternatively in hazardous areas for dusts, for the device category 1D and
group IIIB.
Gefahr durch elektrostatische Entladungen
Potential electrostatic charging hazard
Danger potentiel de charges électrostatiques
Information to be observed during installation, commissioning, operation, cleaning and
disassembly
Installations- und Betriebsbedingungen für den explosionsgefährdeten Bereich:
a) Der Einsatz des Gerätes in der Nähe von stark ladungserzeugenden Prozessen ist untersagt.
b) Das Gerät ist mechanisch geschützt zu montieren.
c) Die Montage muss auf einem geerdeten, leitenden Untergrund erfolgen.
d) Die Reinigung darf nur mit feuchtem Tuch erfolgen.
Installation and operating conditions for hazardous areas:
a) Use of the equipment in the vicinity of processes generating high charges is not allowed.
b) The equipment must be mechanically protected when installed.
c) Installation must be performed on a grounded and conductive mounting surface.
d) Cleaning only with a wet cloth.
Conditions d'installation et de mise en oeuvre pour la zone de protection Ex :
a) L'utilisation de l'appareil près de processus générant de fortes charges est interdite.
b) L'appareil doit être monté de manière à être protégé mécaniquement.
c) Le montage doit être effectué sur un socle conducteur mis à la terre.
d) Nettoyage uniquement avec un chiffon humide.