Advertisement

ISO transponder
8.14 MDS D400
8.14
MDS D400
8.14.1
Features
MDS D400
8.14.2
Ordering data
Table 8-40
MDS D400
Table 8-41
Spacer
(in conjunction with fixing pocket 6GT2190-0AB00)
Fixing pocket
(in conjunction with spacer 6GT2190-0AA00)
Fixing pocket
(not suitable for fixing directly onto metal)
8.14.3
Metal-free area
Direct mounting of the transponder on metal is not permitted. A distance of ≥ 20 mm is
recommended to avoid a reduced read/write range and a reduction of the field data. This can be
accomplished, for example, by installing a spacer.
Note that if the distances (a and h) are not observed, this may result in a reduction of the field
data as well as a reduced write/read range.
352
Characteristics
Area of application
Memory size
Write/read range
Mounting on metal
ISO standard
Degree of protection
Ordering data of MDS D400
Ordering data of MDS D400 accessories
From simple identification such as electronic barcode
replacement/supplementation, through warehouse
and distribution logistics, right up to product identifica‐
tion.
2000 bytes of FRAM user memory
See section "Field data of ISO transponders (MDS D)
(Page 53)"
Yes, with spacer
ISO 15693
IP67
Article number
6GT2600-4AD00
Article number
6GT2190-0AA00
6GT2190-0AB00
6GT2390-0AA00
System Manual, 02/2021, C79000-G8976-C345-09