Ignitions of dust-air mixtures
When using the antenna, check that the temperature class is complied with in connection with
the requirements of the area of application.
Non-compliance with the permitted temperature ranges while using the antenna can lead to
ignitions of gas-air mixtures.
Antenna portfolio for use as simple equipment for gases and dust
You can use the following antennas as simple equipment for gases and dust with the RF350R:
Antenna
ANT 1
ANT 3
ANT 3S
ANT 8
ANT 12
ANT 18
ANT 30
Antenna values Ui, Ii, Pi, Ci, Li for installation in hazardous areas
Note
Read the document "A5E44647714"
Read the information in the document "Control Drawing A5E44647714" shipped with the reader
for installation of the reader RF350R - 2nd generation in a hazardous area.
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
WARNING
Article number
6GT2398-1CB00
6GT2398-1CD40-0AX0
6GT2398-1CD30-0AX0
6GT2398-1CD50-0AX0
6GT2398-1CD60-0AX0
6GT2398-1CF00
6GT2398-1CF10
6GT2398-1CC00
6GT2398-1CC10
6GT2398-1DC00
6GT2398-1DC10
6GT2398-1CA00
6GT2398-1CA10
6GT2398-1CA10-0AX0
6GT2398-1DA00
6GT2398-1DA10
6GT2398-1CC00
6GT2398-1CD10-0AX0
6GT2398-1DC00
6GT2398-1DC10
Readers