5.2 SIMATIC RF310R with Scanmode
Operating frequency, rated value
Electrical data
Output power (antenna input)
Maximum range
Maximum data transmission speed
reader ↔ transponder
Transmission speed
Read/write distances of the reader
Interfaces
Electrical connector design
Standard for interfaces for communication
Antenna
Mechanical specifications
Enclosure
Recommended distance to metal
Supply voltage, current consumption, power loss
Supply voltage
Typical current consumption
Permitted ambient conditions
Ambient temperature
Degree of protection according to EN 60529
Shock-resistant acc. to EN 60721-3-7, Class 7 M2
Vibration-resistant acc. to EN 60721-3-7, Class 7
M2
Torsion and bending load
Design, dimensions and weight
Dimensions (L x W x H)
Weight
Type of mounting
144
1)
Read
Material
Color
During operation
During transportation and storage
13.56 MHz
≃ 0.3 W
60 mm
RF300 transponder
approx. 8000 bytes/s •
9.6, 19.2, 38.4, 57.6, 115.2 kBd
See section "Field data for transponders, readers
and antennas (Page 49)"
M12, 8-pin
RS-422 (Scanmode)
integrated
Plastic PA 12
Anthracite
Mounting on metal permitted
24 VDC
50 mA
-25 ... +70 °C
-40 ... +85 °C
IP67
500 m/s
2
200 m/s
2
Not permitted
79.6 x 55 x 30 mm
170 g
4 x M5 screws;
1.5 Nm
System Manual, 02/2021, C79000-G8976-C345-09
6GT2801-1BA20-0AX1
ISO transponder
approx. 1500 bytes/s
SIMATIC RF300

Advertisement