Download Print this page

Siemens SIMATIC RF300 System Manual page 226

Hide thumbs Also See for SIMATIC RF300:

Advertisement

Antennas
6.4 ANT 8
Degree of protection according to EN 60529
Shock-resistant according to EN 60721-3-7 Class 7
M2
Vibration-resistant according to EN 60721-3-7
Class 7 M2
Design, dimensions and weight
Dimensions (∅ x thread x L)
Weight
Type of mounting
Cable length
1)
Warning: The values for shock and vibration are maximum values and must not be applied continuously.
6.4.7
Dimension drawing
Figure 6-19
226
During transportation and storage
1)
1)
without antenna cable
with antenna cable
The antenna connector may only be tightened by hand.
The cable must be secured in front of/behind the support sleeve so that no bending strain can be
transferred to the antenna connector.
Dimension drawing ANT 8 (all values in mm)
-40 ... +85 °C
IP67 (front)
500 m/s
2
200 m/s
2
M8 x 1 x 38 mm
10 g
140 g
2x stainless steel nuts M8 x 1
3 m
System Manual, 02/2021, C79000-G8976-C345-09
6GT2398-1CF10
6GT2398-1CF00
SIMATIC RF300

Advertisement