Download Print this page

Siemens SIMATIC RF300 System Manual page 387

Hide thumbs Also See for SIMATIC RF300:

Advertisement

Figure 8-64
8.23.4
Technical specifications
Table 8-64
Product type designation
Memory
Memory configuration
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
Mechanical specifications
Enclosure
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
Degree of protection according to EN 60529
Shock-resistant acc. to EN 60721-3-7, Class 7M2
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
Installation example of MDS D421/D521/E623 in a stud bolt
Technical specifications for MDS D521
UID
User memory
)
g
Material
Color
during write/read access
outside the read/write field
during storage
SIMATIC MDS D521
8 bytes
8192 bytes FRAM
> 10
12
> 10
12
> 10 years
Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 53)"
Epoxy resin
Black
≥ 0 mm
Inductive, without battery
-25 ... +85 °C
-40 ... +100 °C
-40 ... +100 °C
IP67
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
1000 m/s
1)
2
ISO transponder
8.23 MDS D521
6GT2600-5AE00