Querythelastrecognizedserialmessageinhexformat; Query The Last Recognized Serial Message In Hash Format; Clear The Stored Last Recognized Serial Message; Query The Last Recognized Serial Message In String Format - Lightware HDMI-TPS-RX110AY Series User Manual

Hdbaset multimedia extender
Table of Contents

Advertisement

 
7.LW3Programmers'Reference
7.10.5. Query the Last Recognized Serial Message in Hex Format
The recognized data is stored in hex format. They are stored until the next incoming message or until the
RECOGNIZER:clear()methodiscalled.

TIPSANDTRICKS:
When one of these properties are set as a condition in the Event Manager, and the
same strings follow each other, the action will execute once.
Command and Response
Î GET·/MEDIA/UART/RECOGNIZER.RxHex
Í pr·/MEDIA/UART/RECOGNIZER.RxHex=
Parameters
<recognized _hex>
Recognized data in hex format.
Example
Î GET/MEDIA/UART/RECOGNIZER.RxHex
Í pr/MEDIA/UART/RECOGNIZER.RxHex=FF1F4C6F67696E3A
7.10.6. Query the Last Recognized Serial Message in Hash Format
The recognized data is stored in hash format. They are stored until the next incoming message or until the
RECOGNIZER:clear()methodiscalled.

TIPSANDTRICKS:
When one of these properties are set as a condition in the Event Manager, and the
same strings follow each other, the action will execute once.
Command and Response
Î GET·/MEDIA/UART/RECOGNIZER.Hash
Í pr·/MEDIA/UART/RECOGNIZER.Hash=
Parameters
<recognized _hash>
Fingerprint code, Max. 32 bit-long recognized data hash.
Example
Î GET/MEDIA/UART/RECOGNIZER.Hash
Í pr/MEDIA/UART/RECOGNIZER.Hash=997A659E
<recognized _hex>
<recognized _hash>
Appliedfirmwarepackage:v1.4.0 | LDCsoftware:v2.4.0b3
HDMI-TPS-RX110AY series – User's Manual
7.10.7. Clear the Stored Last Recognized Serial Message
This method deletes all the stored received serial messages.
Command and Response
Î CALL·/MEDIA/UART/RECOGNIZER:clear()
Í mO·/MEDIA/UART/RECOGNIZER:clear
Example
Î CALL/MEDIA/UART/RECOGNIZER:clear()
Í mO/MEDIA/UART/RECOGNIZER:clear
7.10.8. Query the Last Recognized Serial Message in String Format
The recognized data is stored in string, hex and hash format in a temporary storage. They are erased when
the Active Timeout elapsed.
TIPSANDTRICKS:

When these properties are set as a condition in the Event Manager, and the same
strings follow each other, the action will execute every occasion if the active timeout set properly.
Command and Response
Î GET·/MEDIA/UART/RECOGNIZER.ActiveRx
·
Í pr
/MEDIA/UART/RECOGNIZER.ActiveRx=<recognized _string>
Parameters
<recognized _string>
Max. 12 byte-long recognized data string.
Example
Î GET/MEDIA/UART/RECOGNIZER.ActiveRx
Í pr/MEDIA/UART/RECOGNIZER.ActiveRx=Login:
83

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdmi-tps-rx110ayHdmi-tps-rx110ay-plus9154002191540070

Table of Contents