6.LW2Programmers'Reference
6.6. RS-232 Settings
6.6.1. RS-232 Mode Setting
RS -232 mode can be set as follows. See more details about RS -232 modes in the
#rs232 #rs-232 #serial #commandinjection #protocol
Command and Response
ȩ {RS232=<mode>}
Ȩ (RS232=<mode>)CrLf
Parameters
Identifier
Parameter description
<mode>
RS-232 operation mode
Example
ȩ {rs232=control}
Ȩ (RS232=CONTROL)

INFO:
The current RS-232 mode can be queried by the {RS232=?} command.
HDMI-TPS-RX110AY series – User's Manual
Serial Interface
section.
Value
Parameter value
CONTROL Control mode
CI
Command injection mode
PASS
Pass-through mode
Appliedfirmwarepackage:v1.4.0 | LDCsoftware:v2.4.0b3
6.6.2. Local RS-232 Parameters Settings
The parameters of local RS -232 port can be set as follows.
Command and Response
ȩ {RS232_LOCAL_FORMAT=<BaudRate>;<DataBit>;<Parity>;<StopBit>}
Ȩ (RS232_LOCAL_FORMAT=<BaudRate>;<DataBit>;<Parity>;<StopBit>)CrLf
Parameters
Identifier
Parameter description
<BaudRate>
Baud rate
<DataBit>
Data bit
<Parity>
Parity
<StopBit>
Stop Bit
Example
ȩ {rs232_local_format=9600;8;O;X}
Ȩ (RS232_LOCAL_FORMAT=9600;8;O;X)
Explanation
LocalRS-232portissetasthefollowing:thebaudrateto9600,databitto8,paritytoodd,andstopbitis
not changed, remained 1.
INFO:

ThecurrentlocalRS-232parameterscanbequeriedbythe{RS232_LOCAL_FORMAT=?}command.
60
Value
Parameter value
X
No change
4800
4800
7200
7200
9600
9600
14400
14400
19200
19200
38400
38400
57600
57600
115200
115200
X
No change
8
8
9
9
X
No change
N
None
E
Even
O
Odd
X
No change
1
1
1,5
1,5
2
2