7.LW3Programmers'Reference
7.10.9. Query the Last Recognized Serial Message in Hex Format
The recognized data is stored in string, hex and hash format in a temporary storage. They are erased when
the Active Timeout elapsed.
TIPSANDTRICKS:
When these properties are set as a condition in the Event Manager, and the same
strings follow each other, the action will execute every occasion if the active timeout set properly.
Command and Response
Î GET·/MEDIA/UART/RECOGNIZER.ActiveRxHex
Í pr·/MEDIA/UART/RECOGNIZER.ActiveRxHex=
Parameters
<recognized _hex>
Recognized data in hex format.
Example
Î GET/MEDIA/UART/RECOGNIZER.ActiveRxHex
Í pr/MEDIA/UART/RECOGNIZER.ActiveRxHex=4C6F67696E3A
7.10.10. Query the Last Recognized Serial Message in Hash Format
The recognized data is stored in string, hex and hash format in a temporary storage. They are erased when
the Active Timeout elapsed.
TIPSANDTRICKS:
When these properties are set as a condition in the Event Manager, and the same
strings follow each other, the action will execute every occasion if the active timeout set properly.
Command and Response
Î GET·/MEDIA/UART/RECOGNIZER.ActiveHash
Í pr·/MEDIA/UART/RECOGNIZER.ActiveHash=
Parameters
<recognized _hash>
Fingerprint code, Max. 32 bit-long recognized data hash.
Example
Î GET/MEDIA/UART/RECOGNIZER.ActiveHash
Í pr/MEDIA/UART/RECOGNIZER.ActiveHash=2D8A5E38
#infra #infrared
<recognized _hex>
<recognized _hash>
Appliedfirmwarepackage:v1.4.0 | LDCsoftware:v2.4.0b3
HDMI-TPS-RX110AYseries–User'sManual
7.10.11. Set the Active Timeout
This property is responsible for erasing the temporary storage (ActiveRx, ActiveRxHex, ActiveHash) after the
elapsing time. Default value is 50ms.
Command and Response
SET·/MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=<a_timeout>
Î
pw·/MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=<a_timeout>
Í
Parameters
<a_timeout>
Active timeout value (ms) between 0 and 255.
Example
Î SET/MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=255
Í pw/MEDIA/UART/RECOGNIZER.ActivePropertyTimeout=255
7.11. Infrared Port Configuration
Port Numbering
Infrared port type
Input
Output
7.11.1. Enable Command Injection Mode
Command and Response
SET·/MEDIA/IR/<in|out>.CommandInjectionEnable=<logical_value>
Î
pw·/MEDIA/IR/<in|out>.CommandInjectionEnable=<logical_value>
Í
Parameters
Identifier
<logical_value>
Example
Î SET/MEDIA/IR/S1.CommandInjectionEnable=true
Í pw/MEDIA/IR/S1.CommandInjectionEnable=true
Parameter
Infrared port
IR in (local)
<in>
TPS in (IR in)
IR out (local)
<out>
TPS in (IR out)
Parameter description
Value
true
Command injection is enabled.
Command injection setting
false
Command injection is disabled.
84
LW3 port number
S1
S2
D1
D2
Explanation