YOKOGAWA WT3001E User Manual page 93

Precision power analyzer communication interface
Hide thumbs Also See for WT3001E:
Table of Contents

Advertisement

:FILE:SAVE:NUMeric?
Function
Queries all settings related to the saving of
numeric data files.
:FILE:SAVE:NUMeric?
Syntax
:FILE:SAVE:NUMERIC? ->
Example
:FILE:SAVE:NUMERIC:TYPE ASCII;
NORMAL:ELEMENT1 1;ELEMENT2 0;
ELEMENT3 0;ELEMENT4 0;SIGMA 0;
SIGMB 0;U 1;I 1;P 1;S 1;Q 1;
LAMBDA 1;PHI 1;FU 1;FI 1;UPPEAK 0;
UMPEAK 0;IPPEAK 0;IMPEAK 0;CFU 0;
CFI 0;PC 0;TIME 0;WH 0;WHP 0;WHM 0;
AH 0;AHP 0;AHM 0;WS 0;WQ 0;ETA1 0;
ETA2 0;ETA3 0;ETA4 0;F1 0;F2 0;
F3 0;F4 0;F5 0;F6 0;F7 0;F8 0;F9 0;
F10 0;F11 0;F12 0;F13 0;F14 0;
F15 0;F16 0;F17 0;F18 0;F19 0;F20 0
:FILE:SAVE:NUMeric:CBCycle?
Function
Queries all settings related to Cycle by Cycle
measurement items saved to numeric data files
or queries the current setting
:FILE:SAVE:NUMeric:CBCycle?
Syntax
:FILE:SAVE:NUMERIC:CBCYCLE? ->
Example
:FILE:SAVE:NUMERIC:CBCYCLE
:ELEMENT1 1;ELEMENT2 0;ELEMENT3 0;
ELEMENT4 0;SIGMA 0;SIGMB 0;FREQ 1;
U 1;I 1;P 1;S 1;Q 1;LAMBDA 1
:FILE:SAVE:NUMeric:CBCycle:ALL
Function
Collectively turns ON/OFF the output of all
elements and functions when saving numeric
data from Cycle by Cycle measurement to a file.
:FILE:SAVE:NUMeric:CBCycle:
Syntax
ALL {<Boolean>}
:FILE:SAVE:NUMERIC:CBCYCLE:ALL ON
Example
IM WT3001E-17EN
:FILE:SAVE:NUMeric:CBCycle:{ELEMent<
x>|SIGMA|SIGMB}
Function
Turns ON/OFF the output of {each element | ΣA
| ΣB} when saving numeric data from Cycle by
Cycle measurement to a file.
:FILE:SAVE:NUMeric:
Syntax
CBCycle:{ELEMent<x>|SIGMA|SIGMB}
{<Boolean>}
:FILE:SAVE:NUMeric:
CBCycle:{ELEMent<x>|SIGMA|SIGMB}?
<x> = 1 to 4
:FILE:SAVE:NUMERIC:CBCYCLE:
Example
ELEMENT1 ON
:FILE:SAVE:NUMERIC:CBCYCLE:
ELEMENT1? -> :FILE:SAVE:NUMERIC:
CBCYCLE:ELEMENT1 1
Description • " :FILE:SAVE:NUMeric:CBCycle:SIGMA " is
available for models with 2 elements or more.
Also, to turn output ON, wiring unit ΣA must
exist per the wiring system setting command
([:INPut]WIRing) .
• " :FILE:SAVE:NUMeric:CBCycle:SIGMB " is
valid for models with 4 elements. Also, to turn
output ON, wiring unit ΣB must exist per the
wiring system setting command ([:INPut]
WIRing) .
:FILE:SAVE:NUMeric:CBCycle:<Function>
Function
Turns ON/OFF the output of each function
when saving numeric data from Cycle by Cycle
measurement to a file or queries the current
setting.
:FILE:SAVE:NUMeric:
Syntax
CBCycle:<Function> {<Boolean>}
:FILE:SAVE:NUMeric:
CBCycle:<Function>?
<Function> = {FREQ|U|I|P|S|Q|LAMBda|
SPEed|TORQue|PM}
:FILE:SAVE:NUMERIC:CBCYCLE:U ON
Example
:FILE:SAVE:NUMERIC:CBCYCLE:U? ->
:FILE:SAVE:NUMERIC:CBCYCLE:U 1
Description {SPEed|TORQue|PM} is only available on
models with the motor evaluation function (/MTR
option).
:FILE:SAVE:NUMeric[:EXECute]
Function
Saves the numeric data to a file.
:FILE:SAVE:NUMeric[:EXECute]
Syntax
{<Filename>}
:FILE:SAVE:NUMERIC:EXECUTE "NUM1"
Example
Description • Specify the file name without the extension.