Command
:CURSor:WAVE[:STATe]
:CURSor:WAVE:TRACe<x>
:CURSor:WAVE:{X<x>|DX|PERDt|Y<x
>|DY}?
DISPlay Group
:DISPlay?
:DISPlay:BAR?
:DISPlay:BAR:FORMat
:DISPlay:BAR:ITEM<x>
:DISPlay:BAR:ORDer
:DISPlay:CBCycle?
:DISPlay:CBCycle:CURSor
:DISPlay:CBCycle:ITEM<x>
:DISPlay:CBCycle:PAGE
:DISPlay:FFT?
:DISPlay:FFT:FFT<x>?
:DISPlay:FFT:FFT<x>:LABel
:DISPlay:FFT:FFT<x>:OBJect
:DISPlay:FFT:FFT<x>[:STATe]
:DISPlay:FFT:FORMat
:DISPlay:FFT:POINt
:DISPlay:FFT:SCOPe
:DISPlay:FFT:SPECtrum
:DISPlay:FFT:VSCale
:DISPlay:FFT:WINDow
:DISPlay:FLICker?
:DISPlay:FLICker:ELEMent
:DISPlay:FLICker:PAGE
:DISPlay:FLICker:PERiod
:DISPlay:INFOrmation?
:DISPlay:INFOrmation:PAGE
:DISPlay:INFOrmation[:STATe]
:DISPlay:MATH?
:DISPlay:MATH:CONStant<x>
:DISPlay:MATH:MATH<x>?
:DISPlay:MATH:MATH<x>:EXPRessi
on
:DISPlay:MATH:MATH<x>:LABel
:DISPlay:MATH:MATH<x>:SCALing?
:DISPlay:MATH:MATH<x>:SCALing:C
ENTer
:DISPlay:MATH:MATH<x>:SCALing:M
ODE
:DISPlay:MATH:MATH<x>:SCALing:S
DIV
IM WT3001E-17EN
Function
Turns ON/OFF the cursor display on the waveform display or queries the
current setting.
Sets the cursor target on the waveform display or queries the current setting. 6-28
Queries the cursor measurement value on the waveform display.
Queries all settings related to the screen display.
Queries all settings related to the bar graph.
Sets the display format of the bar graph or queries the current setting.
Sets the bar graph item (function and element) or queries the current setting. 6-29
Sets the start and end orders of the bar graph or queries the current setting. 6-30
Queries all settings related to the Cycle by Cycle display.
Sets the cursor position of the Cycle by Cycle display or queries the current
setting.
Sets the displayed items (function and element) of the Cycle by Cycle display
or queries the current setting.
Sets the number of the displayed page of the Cycle by Cycle display or
queries the current setting.
Queries all settings related to the FFT waveform display.
Queries all settings related to the FFT waveform.
Sets the label of the FFT waveform or queries the current setting.
Sets the source waveform of the FFT computation or queries the current
setting.
Turns ON/OFF the FFT waveform display or queries the current setting.
Sets the display format of the FFT waveform or queries the current setting.
Sets the number of points of the FFT computation or queries the current
setting.
Sets the display range of the FFT waveform or queries the current setting.
Sets the display spectrum format of the FFT waveform or queries the current
setting.
Sets the display scale of the vertical axis of the FFT waveform or queries the
current setting.
Sets the window function of the FFT computation or queries the current
setting.
Queries all settings related to flicker measurement display.
Sets the element to be displayed for flicker measurement display or queries
the current setting.
Sets the page numbers to be displayed for flicker measurement display or
queries the current setting.
Sets the display observation period number for flicker measurement display
or queries the current setting.
Queries all settings related to the display of the setup parameter list.
Sets the page number of the display of setup parameter list or queries the
current setting.
Turns ON/OFF the display of the setup parameter list or queries the current
setting.
Queries all settings related to the computed waveform display.
Sets the constant to be used in the waveform computing equation or queries
the current setting.
Queries all settings related to the computed waveform.
Sets the equation of the waveform computation or queries the current
setting.
Sets the label of the computed waveform or queries the current setting.
Queries all settings related to the scaling of the computed waveform.
Sets the center value of the manual scaling of the computed waveform or
queries the current setting.
Sets the scaling mode of the computed waveform or queries the current
setting.
Sets the scale/division value of the manual scaling of the computed
waveform or queries the current setting.
6.1 List of Commands
Page
6-28
6-28
6-29
6-29
6-29
6-30
6-30
6-30
6-30
6-30
6-31
6-31
6-31
6-31
6-31
6-31
6-31
6-32
6-32
6-32
6-32
6-32
6-32
6-32
6-32
6-32
6-32
6-33
6-33
6-33
6-33
6-33
6-33
6-34
6-34
6-34
6-3
1
2
3
4
5
6
7
App
Index

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wt3002eWt3003eWt3004e

Table of Contents