6.18 NUMeric Group
:NUMeric:FLICker:JUDGement?
Function
Queries the judgment results (fixed format).
:NUMeric:FLICker:JUDGement? {<NRf>|
Syntax
ALL}
:NUMeric:FLICker:JUDGement?
<NRf> = 1 to9 (observation period number)
ALL = Overall observation period (Result)
• Example in which " :NUMeric:FORMat " is set
Example
to "ASCii"
:NUMERIC:FLICKER:JUDGEMENT? 1 ->
0,0,0,0,0,0,0,-1,-1,-1,-1,-1,-1,
-1,-1,-1,-1,-1,-1
• Example in which :NUMeric:FORMat is set to
" FLOat ".
:NUMERIC:FLICKER:JUDGEMENT? -> #4
(number of bytes, four digits) (data byte
sequence)
Description • Only available with the flicker measurement
function (/FL option).
• The contents and order of the judgment results
that are output are in the fixed format below.
To modify the output contents and order, use
the " :NUMeric:FLICker:INFOrmation "
commands.
6-90
Output contents and order of Judgment results
For function names, see the description for " :NUM
eric:FLICker:INFOrmation:ITEM<x> ".
Numbers refer to elements. (ALL) is the overall
judgment result for all measured elements.
JTOTal(ALL)→
JDC1→JDMAX1→JDT1*→JPST1→
JPLT1→JTOTal1→
JDC2→JDMAX2→JDT2*→JPST2→
JPLT2→JTOTal12→(output only for 2 to
4 element models)
JDC3→JDMAX3→JDT3*→JPST3→
JPLT3→JTOTal13→ (output only for 3 to 4
element models)
JDC4→JDMAX4→JDT4*→JPST4→
JPLT4→JTOTal14→ (output only for 4
element models)
* JTMAX1, JTMAX2, JTMAX3, or JTMAX4 for
IEC 61000-3-3 Edition 3.0, JDT1, JDT2, JDT3,
or JDT4 for IEC 61000-3-3 Edition 2.0.
• For 1 element models, 7 data from JTOTal(ALL)
to JTOTal1 are output.
For 2 element models, 13 data from
JTOTal(ALL) to JTOTal2 are output.
For 3 element models, 19 data from
JTOTal(ALL) to JTOTal3 are output.
For 4 element models, 25 data from
JTOTal(ALL) to JTOTal4 are output.
• If parameters are specified, the judgment
results of the specified observation period are
output.
• If parameters are omitted, the judgment result
of the overall observation period (Result) is
output (the same output occurs as when the
ALL parameters are specified).
• For the format of individual numeric data, see
the description for " :NUMeric:FLICker:INF
Ormation:VALue? ".
:NUMeric:FLICker:PERiod?
Function
Queries the observation period number currently
being measured during flicker measurement.
:NUMeric:FLICker:PERiod?
Syntax
:NUMERIC:FLICKER:PERIOD? -> 5
Example
Description • Only available with the flicker measurement
function (/FL option).
• Returns the observation period numbers
marked with an asterisk (*) in the No. column
of the numeric list in the flicker measurement
screen. If no asterisks are displayed (such
as after a reset or during initialization), 0 is
returned.
IM WT3001E-17EN