<Register>
<Register> indicates an integer, and can be expressed
in hexadecimal, octal, or binary as well as a decimal
number. It is used when each bit of the value has
a particular meaning. It is expressed in one of the
following forms.
Form
<NRf>
#H<Hexadecimal value made up of the digits
0 to 9 and A to F>
#Q<Octal value made up of the digits 0 to 7>
#B<Binary value made up of the digits 0 and 1>
• <Register> is not case sensitive.
• Response messages are always expressed as
<NR1>.
<Character Data>
<Character Data> is a specified string of character
data (a mnemonic). It is mainly used to indicate options
and is chosen from the character strings given in { }.
For interpretation rules, refer to "Header Interpretation
Rules" on page 5-4.
Form
{AUTO|NORMal}
• As with the header, the " COMMunicate:VERBose "
command can be used to select whether to return
the response in the full form or in the abbreviated
form.
• The " COMMunicate:HEADer " setting does not
affect the character data.
<Boolean>
<Boolean> is data that indicates ON or OFF. It is
expressed in one of the following forms.
Form
{ON|OFF|<NRf>}
• When <Boolean> is expressed in the <NRf> form,
"OFF" is selected if the rounded integer value is 0,
and ON for all other cases.
• A response message is always returned with a 1 if
the value is ON and 0 if the value is OFF.
<String Data>
<String data> is not a specified character string like
<Character data>. It is an arbitrary character string.
The character string must be enclosed in single
quotation marks ( ' ) or double quotation marks ( " ).
Form
<String data>
IM WT3001E-17EN
Example
1
#H0F
#Q777
#B001100
Example
AUTO
Example
ON OFF 1 0
Example
'ABC' "IEEE488.2-1992"
• If a character string contains a double quotation
mark ( " ), the double quotation mark is replaced by
two concatenated double quotation marks ( "" ). This
rule also applies to a single quotation mark within a
character string.
• A response message is always enclosed in double
quotation marks ( " ).
• <String data> is an arbitrary character string.
Therefore the instrument assumes that the
remaining program message units are part of the
character string if no single ( ' ) or double quotation
mark ( " ) is encountered. As a result, no error is
detected if a quotation mark is omitted.
<Filename>
<Filename> is data that indicates a file name. It is
expressed in one of the following forms.
Form
{<NRf>|<Character data > |<String data>}
• <NRf> is rounded to an 8-digit integer and converted
to ASCII code. The result is the file name (example:
1 becomes "00000001" ). Negative values are not
allowed.
• For <Character data> and <String data>, the first
eight characters become the file name.
• Response messages are always returned in the
<String data> form.
<Block Data>
<Block data> is arbitrary 8-bit data. It is only used in
response messages on this instrument. The syntax is
as follows:
Form
#N<N-digit decimal number><Data byte
sequence>
• #N
Indicates that the data is <Block data>. "N" indicates
the number of succeeding data bytes (digits) in
ASCII code characters.
• <N-digit decimal number>
Indicates the number of bytes of data (example:
0012 = 12 bytes).
• <Data byte sequence>
Expresses the actual data (example:
ABCDEFGHIJKL ).
• Data is comprised of 8-bit values (0 to 255). This
means that the ASCII code "0AH," which stands for
"NL," can also be a code used for data. Hence, care
must be taken when programming the controller.
5.4 Data
1
2
3
4
5
Example
1 CASE "CASE"
6
7
App
Index
Example
#40012ABCDEFGHIJKL