YOKOGAWA WT3001E User Manual page 46

Precision power analyzer communication interface
Hide thumbs Also See for WT3001E:
Table of Contents

Advertisement

6.1 List of Commands
Command
:CBCycle:SYNChronize:SLOPe
:CBCycle:SYNChronize:SOURce
:CBCycle:TIMEout
:CBCycle:TRIGger?
:CBCycle:TRIGger:LEVel
:CBCycle:TRIGger:MODE
:CBCycle:TRIGger:SLOPe
:CBCycle:TRIGger:SOURce
COMMunicate Group
:COMMunicate?
:COMMunicate:HEADer
:COMMunicate:LOCKout
:COMMunicate:OPSE(Operation
Pending Status Enable register)
:COMMunicate:OPSR?(Operation
Pending Status Register)
:COMMunicate:OVERlap
:COMMunicate:REMote
:COMMunicate:STATus?
:COMMunicate:VERBose
:COMMunicate:WAIT
:COMMunicate:WAIT?
CURSor Group
:CURSor?
:CURSor:BAR?
:CURSor:BAR:POSition<x>
:CURSor:BAR[:STATe]
:CURSor:BAR:{Y<x>|DY}?
:CURSor:FFT?
:CURSor:FFT:POSition<x>
:CURSor:FFT[:STATe]
:CURSor:FFT:TRACe<x>
:CURSor:FFT:{X<x>|DX|Y<x>|DY}?
:CURSor:TRENd?
:CURSor:TRENd:POSition<x>
:CURSor:TRENd[:STATe]
:CURSor:TRENd:TRACe<x>
:CURSor:TRENd:{X<x>|Y<x>|DY}?
:CURSor:WAVE?
:CURSor:WAVE:PATH
:CURSor:WAVE:POSition<x>
6-2
Function
Sets the slope of the synchronization source of Cycle by Cycle measurement
or queries the current setting.
Sets the synchronization source for Cycle by Cycle measurement or queries
the current setting.
Sets the timeout value for Cycle by Cycle measurement or queries the
current setting.
Queries all settings related to triggers or queries the current setting.
Sets the trigger level or queries the current setting.
Sets the trigger mode or queries the current setting.
Sets the trigger slope or queries the current setting.
Sets the trigger source or queries the current setting.
Queries all settings related to communications.
Sets whether to add a header to the response to a query (example
DISPLAY:MODE NUMERIC) or not add the header (example NUMERIC).
Sets or clears local lockout.
Sets the overlap command that is used by the *OPC, *OPC?, and *WAI
commands or queries the current setting.
Queries the value of the operation pending status register.
Sets the commands that will operate as overlap commands or queries the
current setting.
Sets remote or local. ON is remote mode.
Queries line-specific status.
Sets whether to return the response to a query using full spelling (example
:INPUT:VOLTAGE:RANGE:ELEMENT1 1.000E+03) or using abbreviation
(example :VOLT:RANG:ELEM 1.000E+03).
Waits for one of the specified extended events to occur.
Creates the response that is returned when the specified event occurs.
Queries all settings related to the cursor measurement.
Queries all settings related to the cursor measurement of the bar graph
display.
Sets the cursor position (order) on the bar graph display or queries the
current setting.
Turns ON/OFF the cursor display on the bar graph display or queries the
current setting.
Queries the cursor measurement value on the bar graph display.
Queries all settings related to the cursor measurement on the FFT waveform
display.
Sets the cursor position on the FFT waveform display or queries the current
setting.
Turns ON/OFF the cursor display on the FFT waveform display or queries
the current setting.
Sets the cursor target on the FFT waveform display or queries the current
setting.
Queries the cursor measurement value on the FFT waveform display.
Queries all settings related to the cursor measurement of the trend display.
Sets the cursor position on the trend display or queries the current setting.
Turns ON/OFF the cursor display on the trend display or queries the current
setting.
Sets the cursor target on the trend display or queries the current setting.
Queries the cursor measurement value on the trend display.
Queries all settings related to the cursor measurement on the waveform
display.
Sets the cursor path on the waveform display or queries the current setting.
Sets the cursor position on the waveform display or queries the current
setting.
Page
6-22
6-23
6-23
6-23
6-23
6-23
6-23
6-23
6-24
6-24
6-24
6-24
6-24
6-24
6-24
6-25
6-25
6-25
6-25
6-26
6-26
6-26
6-26
6-26
6-26
6-26
6-27
6-27
6-27
6-27
6-27
6-27
6-27
6-27
6-28
6-28
6-28
IM WT3001E-17EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wt3002eWt3003eWt3004e

Table of Contents