The LCI Level Up Automatic Leveling System can be manually operated with an electric drill. In the event of
electrical or system failure, this manual method of extending and retracting the jacks can be used. See the
instructions below.
NOTE: Unhook the power unit motor from the power source prior to attempting the manual override
procedure.
1.
Locate the valves that are paired with the front jacks or rear jacks to be manually overridden.
A. Front jacks - Valve located on the front jacks (Fig. 19).
B. Rear Jacks - Valve located on manifold (Fig. 20).
5/32
2.
Using a
" hex wrench, open the valve by turning the manual override set screw clockwise (Fig. 21A).
3.
Remove protective label (Fig. 22A) from power unit to reveal the manual override coupler.
4.
Using an electric drill with a
operate the Level-Up system (Fig. 23).
A. Run the drill forward (clockwise) to retract the front jacks or rear jacks (Fig. 23A).
B. Run the drill in reverse (counterclockwise) to extend the front jacks or rear jacks (Fig. 23B).
5.
Be sure to turn the manual override set screw on the valve (Fig. 24A) back to the counterclockwise
position after extending or retracting the front jacks or rear jacks.