User Alarm Mode

If the alarm system detects that the parking brake has been disengaged while at least one jack is not fully
retracted and the sensor value changes in any axis more than a predefined amount, the touch pad will buzz
and the LED will signal this error to the user. The system will perform an automatic retract. No other features
are available in this mode.

Miscellaneous

1.
The leveling system will automatically shut off after being idle for 4 minutes.
2.
A "Re-Level" feature is programmed into the controller. If the jacks are extended and the user presses
"AUTO LEVEL" again the system will re-level from that point. The system will not retract before
performing the re-level.
3.
System will refuse any operation when a low voltage condition is present.
4.
System will automatically alarm and retract if park brake is disengaged and jacks are not retracted with
any change in sensor readings. In alarm mode, the only available feature is to retract all jacks.

Low Voltage Signal

1.
The vehicle requires 12.75V DC to operate in the AUTO mode. If the voltage is too low, the screen will
display "LOW VOLTAGE."
2.
Minimum Voltage - If voltage drops below 9.5V DC during AUTO or MANUAL operation, "LOW
VOLTAGE" will appear in the screen and the system will cease operating.
NOTE: Coach will operate in manual mode between 9.5V DC and 12.75V DC.