Functional Description

4
Functional Description
The DULCOMETER
®
Multi-parameter Controller diaLog DACb is a
controller platform manufactured by ProMinent.
In the remainder of this document, the term
'controller' is consistently used for the
DULCOMETER
®
. The controller has been
developed for continuous measurement and
control of liquid analysis parameters. For water
treatment processes in environmental tech‐
nology and industry. The controller is available
in a version with 2 or 3 measuring channels.
The controller can operate together with con‐
ventional analogue sensors and actuators. The
controller is equipped to communicate with dig‐
ital sensors and actuators via the CANopen
sensor/actuator bus.
Typical applications:
Potable water treatment,
n
Waste water treatment,
n
Industrial and process water treatment,
n
Swimming pool water treatment.
n
Standard equipment:
1 measuring channel with 14 freely select‐
n
able measured variables (via mV or mA
input) – depending on the identity code.
PID controller with frequency-based
n
metering pump control for 2 metering
pumps.
2 analogue outputs for measured value,
n
correction value or control variable
(dependent on the optional equipment).
4 digital inputs for sample water fault
n
detection, pause and parameter switch-
over.
2 relays with limit value functions, timer
n
and non-continuous control, 3-point step
control (dependent on the optional equip‐
ment).
Power supply 20 V DC.
n
26
Measured variables and language selec‐
n
tion during commissioning.
Temperature compensation for the pH and
n
fluoride measured variables.
22 operating languages.
n
Saving and transfer of device parametrisa‐
n
tion to an SD card.
Subsequent upgrade of the software func‐
n
tion by means of an activation key or firm‐
ware update.
Disturbance variable processing (flow) via
n
frequency.
Measured value trend display via the con‐
n
troller display.
Optional accessories:
Third complete measuring and control
n
channel with 14 freely selectable meas‐
ured variables (via mV or mA input).
PC configuration software.
n
Data and event logger with an SD card.
n
Disturbance variable processing (flow)
n
also via mA.
Compensation of the influence of pH on
n
chlorine measurement.
3 additional digital inputs, e.g. for level
n
monitoring.
PROFIBUS
®
-DP *.
n
Modbus-RTU.
n
PROFINET
.
®
n
Visualisation via LAN/WLAN web access.
n

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DULCOMETER diaLog DACb and is the answer not in the manual?

Questions and answers

Natalie
January 25, 2025

How do I calibrate measuring channel

User image 67945bcac35fb
1 comments:
Mr. Anderson
May 14, 2025

To calibrate a measuring channel on a ProMinent diaLog DACb:

1. Select the channel to be calibrated (e.g., Channel 1: Chlorine).
2. Access the [Calibration] menu from the continuous display.
3. Follow the on-screen instructions to perform the calibration.
4. Adjust the value using the appropriate buttons if prompted.
5. Import the calibration result into the controller memory by pressing the confirmation button.
6. The controller will return to the continuous display and use the new calibration values.

If calibration values are outside specified limits, an error message appears, and the calibration is not saved. In that case, check conditions, correct any issues, and repeat the calibration. Each measuring channel must be calibrated separately.