Functional Description - ProMinent DULCOMETER Assembly And Operating Instructions Manual

Multi-parameter controller dialog daca
Table of Contents

Advertisement

5

Functional description

The DULCOMETER
Multi-parameter Controller diaLog DACa
is a controller platform from ProMinent. In
the remainder of this document, the term
'controller' is consistently used for the
DULCOMETER
®
. The controller has been
developed for continuous measurement
and control of liquid analysis parameters.
For water treatment processes in environ‐
mental technology and industry. The con‐
troller is available in versions with one and
two measurement channels. The con‐
troller can operate together with conven‐
tional analog sensors and actuators. The
controller is equipped to communicate
with digital sensors and actuators via the
CANopen sensor/actuator bus.
Typical applications:
Potable water treatment
n
Waste water treatment
n
Industrial and process water treat‐
n
ment
Swimming pool water treatment
n
Standard equipment:
One measuring channel with 14 freely
n
selectable measured variables (via
mV or mA input)
PID controller with frequency-based
n
metering pump control for 2 metering
pumps
Two analog outputs for measured
n
value, correcting value, or control var‐
iable (dependent on the optional
equipment)
Two digital inputs for sample water
n
error identification, pause and param‐
eter switching
®
Functional description
Two relays with limit value function,
n
timer and discontinuous control, 3-
point stepper control (dependent on
the optional equipment)
Measured variables and language
n
selection during commissioning
Temperature compensation for the pH
n
and fluoride measured variables
22 operating languages
n
Saving and transfer of device para‐
n
metrisation using an SD card
Retrospective upgrading of the soft‐
n
ware function using activation key or
firmware update
Disturbance variable processing
n
(flow) via frequency
Measured value trend display via the
n
controller display
Optional accessories:
Second, complete measuring and
n
control channel with 14 freely select‐
able measured variables (via mV or
mA input)
PC configuration software
n
Data and event logger with an SD
n
card
Disturbance variable processing
n
(flow) via mA
Compensation of the pH influence on
n
chlorine measurement
3 additional inputs, e.g. for level moni‐
n
toring
PROFIBUS
®
-DP *.
n
Modbus-RTU
n
Visualisation via LAN/WLAN web
n
access
23