Supplementary instructions DULCOMARIN ® Function extension with M, A and P module Please carefully read these operating instructions before use! · Do not discard! The operator shall be liable for any damage caused by installation or operating errors! Technical changes reserved. 985558 BA DC 079 04/12 EN Only valid with the complete operating instructions DULCOMARIN...
Page 3
Supplemental instructions General non-discriminatory approach In order to make it easier to read, this document uses the male form in grammatical structures but with an implied neutral sense. It is aimed equally at both men and women. We kindly ask female readers for their understanding in this simplification of the text.
Table of contents Table of contents Function MAP............... 5 Circulation quantity allocation..........6 2.1 Specification of the respective circulating operating conditions..............8 Flow control [water flow] ............9 Timer settings..............12 Water top-up............... 14 Control of the backwashing valves........15 Index...................
Function MAP Function MAP Function extension with M, A and P With the standard modules M, A, and P it is possible to activate the module following additional functions: Water level (4) with topping up (5) Sensor cap (3) with/without paddle switch (2) Automatic backwashing (1) Heating control (7) Gutter cleaning function (6)
Circulation quantity allocation Circulation quantity allocation The following circulation operating points are specified under this menu item. The setting options in this menu item include: Normal mode Backwashing [ECO min] circulation For an efficient and ecological operation you must match the data of the circulating pump to the analog signal.
Page 7
Circulation quantity allocation Now you must first activate the analog outputs: Analog output 2 [Iout2] for circulation 1 (UW1) – Analog output 4 [Iout4] for circulation 2 (UW1) – System DXMaA R1 R2 R3 K1 K2 K3 Iout1 Iout2 Iout3 Iout4 Pump connectors recorder R1: pH lowering pump...
Flow control [water flow] Flow control [water flow] NOTICE! Alarm during logical checking Cause: Alarm during logical checking. Fault: The flow control reports that a water flow exists, although the circulating pump is off. Measure: The controller triggers an alarm. The flow control must be checked.
Page 10
Flow control [water flow] System DXMaA R1 R2 R3 K1 K2 K3 Iout1 Iout2 Iout3 Iout4 Pump connectors recorder R1: free Iout1: pH value K1: Liquid level Iout2 : ControlCirculation 1 K1 Type: N C Iout3 :Chlorine value Time: 30 s Iout4 : ControlCirculation 2 free...
Page 11
Flow control [water flow] Using the arrow keys enter your password and then press [ENTER] key ð The configuration menu for your A module is now dis‐ played. Select the desired parameters to be changed using the arrow [ENTER] key keys and then press the ð...
Timer settings Timer settings Cause: Timer setting, this means the circulation is only active if the operator activates this circulation for bathing/swimming operation. The operating status of your overall system can change at any time during the automatic operation of the controller.
Page 13
Timer settings Using the arrow keys enter your password and then press [ENTER] key ð You can now see the configuration menu of the A module [OPTION] [Circ.] using the horizontal arrow Select the desired file card [ENTER] key keys and then press the [Circ.] ð...
Water top-up Water top-up An automatic water top-up can be carried out in the skimmer or surge water tank using a level contact. Please note that the drinking water connection may not be con‐ nected to the pool circuit. See the corresponding DVGW (German Gas and Water Association) or FIGAWA (German Federal Associ‐...
Control of the backwashing valves Control of the backwashing valves NOTICE! The default state of the backwashing valves is deener‐ gised (voltage free) Fault: No backwashing is possible if the backwashing valves cannot be controlled. Consequence: The hygiene parameters worsen and the hydraulic resistance of the filter increases.
Index Index 1, 2, 3 ... Question: What functions does MAP give me?..5 6-way valve............15 Question: What is the purpose of flow control?..9 Question: What setting options do I have with circulation quantity allocation?....... 6 Automatic water top-up........14 Question: What settings can I make at the timer?..............