ProMinent DULCOMARIN II Supplementary Instructions Manual

ProMinent DULCOMARIN II Supplementary Instructions Manual

Function extension with m, a and p module
Hide thumbs Also See for DULCOMARIN II:

Advertisement

Supplementary instructions
DULCOMARIN
II
®
Function extension with M, A and P module
Please carefully read these operating instructions before use! · Do not discard!
The operator shall be liable for any damage caused by installation or operating errors!
Technical changes reserved.
985558
BA DC 079 04/12 EN
Only valid with the complete operating instructions DULCOMARIN
®
II

Advertisement

loading
Need help?

Need help?

Do you have a question about the DULCOMARIN II and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ProMinent DULCOMARIN II

  • Page 1 Supplementary instructions DULCOMARIN ® Function extension with M, A and P module Please carefully read these operating instructions before use! · Do not discard! The operator shall be liable for any damage caused by installation or operating errors! Technical changes reserved. 985558 BA DC 079 04/12 EN Only valid with the complete operating instructions DULCOMARIN...
  • Page 2 ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5 - 11 69123 Heidelberg Telephone: +49 6221 842-0 Fax: +49 6221 842-419 email: info@prominent.de Internet: www.prominent.com 985558, 1, en_GB © 2012...
  • Page 3 Supplemental instructions General non-discriminatory approach In order to make it easier to read, this document uses the male form in grammatical structures but with an implied neutral sense. It is aimed equally at both men and women. We kindly ask female readers for their understanding in this simplification of the text.
  • Page 4: Table Of Contents

    Table of contents Table of contents Function MAP............... 5 Circulation quantity allocation..........6 2.1 Specification of the respective circulating operating conditions..............8 Flow control [water flow] ............9 Timer settings..............12 Water top-up............... 14 Control of the backwashing valves........15 Index...................
  • Page 5: Function Map

    Function MAP Function MAP Function extension with M, A and P With the standard modules M, A, and P it is possible to activate the module following additional functions: Water level (4) with topping up (5) Sensor cap (3) with/without paddle switch (2) Automatic backwashing (1) Heating control (7) Gutter cleaning function (6)
  • Page 6: Circulation Quantity Allocation

    Circulation quantity allocation Circulation quantity allocation The following circulation operating points are specified under this menu item. The setting options in this menu item include: Normal mode Backwashing [ECO min] circulation For an efficient and ecological operation you must match the data of the circulating pump to the analog signal.
  • Page 7 Circulation quantity allocation Now you must first activate the analog outputs: Analog output 2 [Iout2] for circulation 1 (UW1) – Analog output 4 [Iout4] for circulation 2 (UW1) – System DXMaA R1 R2 R3 K1 K2 K3 Iout1 Iout2 Iout3 Iout4 Pump connectors recorder R1: pH lowering pump...
  • Page 8: 2.1 Specification Of The Respective Circulating Operating Conditions

    Circulation quantity allocation 2.1 Specification of the respective circulating operating conditions The additional circulating operating conditions: Circulation capacity normal operation – in %, adjustable 0 ... 100 % Backwashing circulation capacity – in %, adjustable 0 ... 100 % ECO Mode min circulation capacity –...
  • Page 9: Flow Control [Water Flow]

    Flow control [water flow] Flow control [water flow] NOTICE! Alarm during logical checking Cause: Alarm during logical checking. Fault: The flow control reports that a water flow exists, although the circulating pump is off. Measure: The controller triggers an alarm. The flow control must be checked.
  • Page 10 Flow control [water flow] System DXMaA R1 R2 R3 K1 K2 K3 Iout1 Iout2 Iout3 Iout4 Pump connectors recorder R1: free Iout1: pH value K1: Liquid level Iout2 : ControlCirculation 1 K1 Type: N C Iout3 :Chlorine value Time: 30 s Iout4 : ControlCirculation 2 free...
  • Page 11 Flow control [water flow] Using the arrow keys enter your password and then press [ENTER] key ð The configuration menu for your A module is now dis‐ played. Select the desired parameters to be changed using the arrow [ENTER] key keys and then press the ð...
  • Page 12: Timer Settings

    Timer settings Timer settings Cause: Timer setting, this means the circulation is only active if the operator activates this circulation for bathing/swimming operation. The operating status of your overall system can change at any time during the automatic operation of the controller.
  • Page 13 Timer settings Using the arrow keys enter your password and then press [ENTER] key ð You can now see the configuration menu of the A module [OPTION] [Circ.] using the horizontal arrow Select the desired file card [ENTER] key keys and then press the [Circ.] ð...
  • Page 14: Water Top-Up

    Water top-up Water top-up An automatic water top-up can be carried out in the skimmer or surge water tank using a level contact. Please note that the drinking water connection may not be con‐ nected to the pool circuit. See the corresponding DVGW (German Gas and Water Association) or FIGAWA (German Federal Associ‐...
  • Page 15: Control Of The Backwashing Valves

    Control of the backwashing valves Control of the backwashing valves NOTICE! The default state of the backwashing valves is deener‐ gised (voltage free) Fault: No backwashing is possible if the backwashing valves cannot be controlled. Consequence: The hygiene parameters worsen and the hydraulic resistance of the filter increases.
  • Page 16: Index

    Index Index 1, 2, 3 ... Question: What functions does MAP give me?..5 6-way valve............15 Question: What is the purpose of flow control?..9 Question: What setting options do I have with circulation quantity allocation?....... 6 Automatic water top-up........14 Question: What settings can I make at the timer?..............