Amtech Axpert-Eazy Series Instruction Manual page 207

Ac drive
Table of Contents

Advertisement

15
Over Speed Fault Reserved
For example if the bit 0 of 40080 is 1 then the Thermistor Over Temperature fault has occurred.
40081– 40082. Status Codes
Access – Read Only
Resolution – 1
It contains information about current status of the system. It has bit level information.
Bit No
Status Code1 (40081) Status Code2 (40082)
0
Normal Run
1
Drive Stopped
2
Acceleration
3
Deceleration
4
Auto Tuning
5
Speed Search
6
DC Breaking
7
Motor Direction
8
Current Limit
9
Power Off
10
PLCT
11
Voltage Limit
12
Torque Mode
13
Precharge Complete
14
Sleep mode
15
Auto Tune select
40110. Control Word
Access – Read/Write
Resolution – 1
It contains information about system configuration. It has bit level information.
Bit
Status
No
0
S Curve Selection
(A205)
1
Ramp Down/Coast to
Stop (A304)
2
Motor Direction (A305) Select direction of motor rotation.
3
Auto Torque Boost
(A502)
4
Open Phase Protection
(C307)
Axpert-Eazy AC Variable Frequency Drive
IU-5 Current
Sensor Fail
Accel1/Accel2 (0/1)
Start Delay
Jogging
Fault
Auto Restart
Auxiliary Drive
Emergency Stop
Password
Factory Password
RUN
Contact Amtech
KEB active
Reserved
Reserved
Reserved
Reserved
Description
This will enable the s-curve shape during acceleration
/deceleration.
= 0: Disable = 1: Enable
Select the stop method.
= 0: Ramp down to stop =1: Coast to stop
= 0: Forward = 1: Reverse
When automatic torque boost is selected, the R1 drop
compensation and slip compensation functions will be valid.
= 0: Disable = 1: Enable
Output open-phase is detected if one phase current is <5%
and other two phase currents are >10% of motor rated
Reserved
Reserved
10
WP
11
11.19

Hide quick links: