4.4.3.2

Step properties

Configuration
You can configure the following property groups for each step or substep:
● Step
● Step configuration
● Miscellaneous
● Step scripts
Step
The following settings are available for the property group "Step":
Name
Components
ID namespace
ID
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE
A name can be assigned to each step.
This name is not relevant for the functioning, but can help the expert in Expert and the operator on
the machine with regard to content and meaning of the step.
Use the button
to open the "Component list" dialog.
The available components are listed in the "Component list" dialog. You can change their order
using the arrow keys
You can link new
or existing
The "Component Explorer" dialog opens for this purpose. Here you can create new components or
link existing components.
Components can also be deleted from the Component list.
You can "Delete the link from the step"
be linked again via the Component explorer or the component is irrevocably deleted
The components are executed according to the order of their listing from top to bottom when exe‐
cuting the package, provided that the step activation is "green" and the step execution is not skipped
due to step scripts.
No components must be linked to steps. Steps can also be created for organizational reasons only,
e.g. for querying conditions, etc.
The ID namespace is only displayed if a step from a subproject was linked into a main project.
The newly linked step is assigned a unique namespace in the main project.
The designation of the namespace can be changed.
Further information on the namespace (Page 235).
When it is created, a step is assigned an ID which is unique in the project.
This can be subsequently adapted. Either numeric values or alphanumeric values starting with a
letter or '_' are permitted.
While executing the step, the activation state of the step can be queried (from other steps or in
scripts) using its ID.
Further information on the step activation and ID can be found in the System variables reference
list - Steps tab (Page 384) section.
on the top right.
component(s) via the buttons top left.
; this results in the component being retained and it can
Create MyConfig - Expert
4.4 Project folder
.
229