Siemens SINUMERIK 840D sl Operating Manual page 424

Integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Create MyConfig - Expert
4.13 Command line call
Parameter
Significance of the switch
Table 4-60
Expert parameters
Switch
Arguments
/silent
-
/deploy
-
/config
(<"Path configuration
file>")
/protect
-
/log
(<"Path log file>")
* This switch must not be used for the verification run (Page 426).
The replacements of the switches, valid up to version V4.6, are listed in the following table.
Table 4-61
Replacement of the switches (valid up to version V4.6)
Switches valid up to version V4.6
/pack "<project file path>"
/deploy "<deployment name>"
/deploydir "<deployment directory>" Up.$Pack.DeployDir="Deployment directory"
/target< NCU | PCU | UAZ >
/uss"<path of the uss file>"
/ust"<path of the ust file>"
/tgz"<path of the tgz file>"
/sdb"<path of the sdb file>"
/utz"<path of the utz file>"
424
Optional
Description
No*
The graphical user interface of Create MyConfig Expert is hidden.
No*
The switch causes the specified project to be verified and deployed.
Yes
The switch causes the configuration file (*.upcfg) to be processed
when calling Expert after opening the project.
In addition to the defined system variables, system variables that are
equivalent to the out-of-date switches can be included in this config‐
uration file.
Further information can be found in the following table, "Replacing
switches (valid up to version V4.6)".
Note
The configuration files (*.upcfg) are generated and exported with Ex‐
pert.
Further information can be found in the "Managing and using config‐
urations" (Page 243) section.
Yes*
Reimport protection can be set. The deployed packages can no lon‐
ger be reimported using Expert.
Yes*
Alarms and faults are written to the log file (XML format) when check‐
ing and deploying the package.
If the argument is not specified, the log file with the name of the pack‐
age in the current work folder (where the batch or CMD was called)
is generated.
Replacement by system variables (valid from version V4.7)
Path of the project file after calling expert.exe
Example: expert.exe D:\Projects\MyProject.upz
Up.$Pack.DeployName="Deployment name"
Up.$Pack.DeployTarget=Up.$Pack.DeployTargets.LINUX
Up.$Dialog.StepSelection.CfgFile="Path of the uss file"
Up.$Dialog.DriveTopology.UstFile="Path of the ust file"
Up.$Dialog.NcuSetup.TgzFile="Path of the tgz file"
Up.$Dialog.SystemConfig.SdbFile="Path of the sdb file"
Up.$Dialog.DriveTopology.UtzFile="Path of the utz file"
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents