Siemens SINUMERIK 840D sl Operating Manual page 467

Integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Property
Description
Name
Name of the component.
C no.
The CU-related SINAMICS component number
is displayed or specified.
C status
Setting options:
● HW available, inactive (p1x5=0)
● HW available, active (p1x5=1)
● HW not available, inactive (p1x5=2)
OEM ID
Identifier of the component in the catalog of the
machine manufacturer.
Description
Free description of the component.
DO
DO type
Assignment of a DO to a component type.
DO No.
DO number via which a drive object is addressed. It is a property of the DO variable and can be modi‐
DO name
Freely selectable name for a drive object.
DO status
Setting options:
● 0 inactive, available
● 1 active, available
● 2 not available
Description
Description of the DO.
Axis-drive assign‐
Select the axis-drive assignment via this button. -
ment
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE
Create MyConfig - Topo
Note
Component names must be unique and have a
maximum of 50 ASCII characters.
The component number can be edited. The follow‐
ing rules apply:
● The SINAMICS component number range lies
between 1 and 199.
● Component number 1 is assigned automatically
for Control Units and cannot be edited.
● The component number must be unique for a
Control Unit.
● For all other components, the component
number can be in the range from 2 to 193 for a
control unit (CU320, NCU or NX) (6 C numbers
are reserved for CU-LINK DOs).
● In the topology configurator, the component
numbers can be automatically reassigned or
added via the context menu when selecting a
bus or slave.
● The default value is "HW available, active".
● Cannot be changed for CU320 and NCU control
units.
● Also cannot be changed for DOs that only
consist of one component.
Only numbers can be used.
The description is used only for the documentation
and is not transferred to the control.
It is a property of the DO variable and can be modi‐
fied only via the DO variable list (Page 470).
fied only via the DO variable list (Page 470).
It is a property of the DO variable and can be modi‐
fied only via the DO variable list (Page 470).
DO names can have a maximum of 24 ASCII char‐
acters.
● The default value is "1 active, available".
● The "active" status cannot be changed for the
DO types "Integrated (NCU)" and
"SINAMICS S".
-
6.4 Topo - operation
467

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents