Procedure
1. Import the packages with the appropriate older Expert version.
2. Open and convert the created project with the current CMC Expert.
3. Store the project and forward it as package with the current version (*.exe, *uaz, *usz).
4.2.5.2

Changes to system variables

Note
Changes to system variables
For Create MyConfig, as of version 4.7 SP2, there have been changes to the system variables
for the NCU/PPU initial state and System configuration dialogs.
Take note of the following section.
New NCU/PPU initial state dialog
The "Data backup of CF card" function has been removed from the "NCU/PPU access" dialog
page and moved to the new "NCU/PPU initial state" dialog page. As a result, after execution
of the "NCU/PPU access" dialog page using script based on the determined software release,
a decision can be made as to whether it is necessary to execute the "NCU/PPU initial state"
(Backup) dialog page.
The involved system variables have changed, although they are still accepted in configuration
files. In scripts, an error message is issued in the verification run and an adjustment must be
made.
Up.$Dialog.NcuAccess.Backup
Up.$Dialog.NcuAccess.Archive
System configuration dialog
The "Use data" property in the "System configuration" dialog has been removed.
Thus, the "Use data" configuration in the "System configuration" dialog for the NC, PLC and
DRV control areas is no longer possible.
The following system variables have been dropped:
● Up.$Dialog.SystemConfig.NcProcess
● Up.$Dialog.SystemConfig.PlcProcess
● Up.$Dialog.SystemConfig.DrvProcess
The affected system variables are ignored in configuration files. In scripts, an error message
is issued in the verification run and an adjustment must be made.
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE
Up.$Dialog.NcuOrigin.Backup
Up.$Dialog.NcuOrigin.Archive