Maintenance - Fuji Electric Micro-Controller X Socket type Operation Manual

Digital temperature controller
Table of Contents

Advertisement

If the voltage exceeds 50 V DC (which is called as hazardous voltage), install a basic insulation between all
terminals and the ground, and supplementary insulation on the digital outputs.
Note that the insulation class for this equipment is as follows. Before installing, please confirm that the insulation
class for equipment meets usage requirements.
Basic insulation
(1500 V AC)
Power supply (100 to 240 V AC)
Power supply (24 V DC/AC)
Control output 1 (relay contact)
Alarm output 1 and 2 (relay contact)
In case where damage or problems with this equipment may lead to serious accidents, install appropriate external
protective circuits.
As this equipment has no power switch or fuse, install them separately as needed.
If you install a fuse, be sure to place it between the main power switch and this equipment. (Main power switch:
double-pole breaker, fuse rating: 250V, 1A)
A power switch or a circuit breaker should be installed within the power supply facility.
A power switch or a circuit breaker should be properly installed within easy reach of an operator.
A power switch or a circuit breaker should be identified as the one for this product.
Electrical wiring must be made by the qualified personnel only and in accordance with your local and national
standards.
For power supply wiring, use a wire equivalent equal to 600 V vinyl insulated wire or higher level.
To prevent damage and failure of the equipment, provide the rated power voltage.
To prevent shock and equipment failure, do not turn the power ON until all wiring is complete.
Before turning on power, confirm that clearance space has been secured to prevent shock or fire.
Do not touch the terminal while the machine is on. Doing so risks shock or equipment errors.
Never disassemble, convert, modify or repair this equipment. Doing so risks abnormal operation, shock or fire.
If any failure occurs, please contact the manufacturer and return the product.
Output relay is the part has a limited life. When output relay contact comes to the end of its life, it might remain
on-state, or off-state. For safety, use a protective circuit outside.
The factory default setting of this equipment is as follows. Change the setting as necessary so as the equipment to
meet your application. Please note that the improper settings may result in overheat or unexpected damage. For
the details of operation, refer to this manual.
• Control output 1: heating control
• Alarm output 1 to 2 (optional): No function
Symbols on the instrument
: Read this instruction manual thoroughly before using the product, and usethe product safely.

Maintenance

When installing or removing the equipment, turn the power OFF. Otherwise, shock, operational errors or failures
may be caused.
Periodic maintenance is recommended for continuous and safe use of this equipment.
Some parts installed on this equipment have a limited life and/or may deteriorate with age.
The warranty period for this unit (including accessories) is three years after the date of manufacture, if the
product is used properly.
Functional
insulation (500 V AC)
Internal circuit
Process value input
Control output 1 (SSR drive, current)
3
No insulation