Download Print this page

Fuji Electric PUMCE Instruction Manual

Multi-loop module type temperature controller enhanced communication module

Advertisement

Quick Links

Instruction Manual (Installation)
Multi-loop module type Temperature Controller
Enhanced Communication Module
Thank you for purchasing the Fuji module type temperature controller.
Once you have confirmed that this is the product you ordered, please use it in accor-
dance with the following instructions.
For detailed information on operating this equipment, please refer to the separate
user's manual.
In addition, please keep this instruction manual within easy reach of the actual person
using this equipment.
.
The contents of this manual are subjected to change without notice.
This manual is compiled with possible care in the interests of accuracy, however,
Fuji Electric shall not be held liable for any damages, including indirect damage,
caused by typographical errors, absence of information or use of information in
this manual.
Scope of application
• This equipment must be used under the following conditions:
- the use of the equipment incurs no risk of a serious accident even if a failure or mal-
function occurs on the equipment, and
- in case of product failure or malfunction, safety measures such as redundant design,
prevention of malfunction, fail safe system, foolproof mechanism are provided outside
of the equipment.
• This product is designed and manufactured as a general-purpose product for general
industrial applications.
• The warranty does not apply to the following cases:
- for the use not described in or beyond the conditions or environment specified in the
instruction manual or the user manual,
- for the use which has large influence on publicity including nuclear power and other
power generation, gas, and/or water,
- for the use in which safety is especially required, because it may seriously affect rail-
roads, vehicles, combustion equipment, medical equipment, entertainment devices,
safety equipment, defense equipment, and/or human lives and property.
However, we will study the possibility of application of the equipment for the above
use, if the user limits the usage of it and agrees to require no special quality. Please
consult us.
Confirming Specifications and Accessories
Before using the product, confirm that it
matches the type ordered.
(Refer to page 4 for model codes.)
Confirm that all of the following accesso-
ries are included.
Temperature Controller Enhanced
Communication Module (Ethernet Com-
munication)
1 Unit
Instruction Manual
1 Copy
Please Read First (Safety Warnings)
Please read this section thoroughly before use and observe the mentioned safety
warnings fully.
Safety warnings are classified into "Warning", "Caution" and "Risk of Electrical Shock".
Warning
Improper use of the equipment may result in death or serious injuries.
Caution
Improper use of the equipment may cause injury or property damage.
Risk of
A risk of electrical shock is present and the associated warning should
Electrical
be observed.
Shock
1
Warranty
1-1 Period of warranty
Warranty period for this product including accessories is one year after delivery.
1-2 Scope of warranty
(1) If any failure or malfunction attributable to Fuji Electric occurs in the period of war-
ranty, we will replace the product or failed parts without charge. Please note that, in
the case where our engineer needs to visit your place for replacement, we cannot
provide commissioning and/or readjustment for whole system using our products.
(Ethernet communication)
Model: PUMCE
INP-TN1PUMCEa-E
CAUTION
Related Information
Refer to "Module Type Temperature
Controller Enhanced Communication
Module (Ethernet Communication)
User's Manual" for details about the
items described in this manual.
Content
Material
name
Specification Catalog
Operating
Ethernet
instruction
Communi-
cation Mod-
ule User's
manual
Tool
PUM
parameter
loader
The warranty does not apply to failure or malfunction resulting from:
a) inappropriate conditions, environment, handling or usage that is not instructed in
a catalog, instruction book or user's manual, or overuse of the product,
b) other devices or software not originate in Fuji Electric,
c) improper use, or an alteration or repair that is not performed by Fuji Electric,
d) factors that do not originate in the purchased or delivered product,
e) damages incurred during transportation or fall after purchase,
f) factors that were not foreseeable by the practical application of science and
technology at the time of purchase or delivery,
g) any reason that Fuji Electric is not responsible for, including a disaster or natural
disaster such as earthquake, thunder, storm and flood damage, or inevitable
accidents such as abnormal voltage.
(2) Regardless of the time period of the occurrence, Fuji Electric is not liable for the
damage caused by the factors Fuji Electric is not responsible for, opportunity loss
of the purchaser caused by malfunction of Fuji Electric product, passive damages,
damage caused due to special situations regardless of whether it was foreseeable
or not, and secondary damage, accident compensation, damage to products that
were not manufactured by Fuji Electric, and compensation towards other opera-
tions.
1-3 Period for repair and provision of spare parts after product discontinuation (maintenance period)
The discontinued models (products) can be repaired for five years from the date of
discontinuation.
Also, most spare parts used for repair are provided for five years from the date of dis-
continuation. However, some electric parts may not be obtained due to their short life
cycle. In this case, repair or provision of the parts may be difficult in the above period.
Please contact Fuji Electric or its service providers for further information.
2
Warning
2-1 Installation and Wiring
• This equipment is intended to be used under the following conditions.
Ambient temperature
Ambient humidity
Warm-up time
Installation category
Pollution level
• The insulation class of the equipment is as below. Before installing, confirm that the
insulation class for the equipment meets usage requirements.
- In cases where damages or problems with this equipment may lead to serious ac-
cidents, install appropriate external protective circuit.
- To avoid product failure or damage, provide the rated power voltage.
- To prevent electric shock and equipment failure, do not turn the power ON until all
wiring is completed.
- Before turning the power ON, make sure clearance space has been secured for
Material No.
shock or fire prevention.
- Do not touch the terminal while the machine is ON. There are risks of shock or equip-
21B1-E-
ment errors.
0054
- Never disassemble, convert, modify or repair this equipment. There are risks of
INP-
abnormal operation, shock or fire.
TN5A2052-E
- All of the wiring should be class 1 type wiring, or the low voltage wires should be
routed separately from the hazardous voltage wires to ensure separation of circuits.
- When using a AWG-16 cable, you should use the crimp terminal that material thick-
ness is 0.9mm or less.
INP-
- Do not use any electrical components that have gotten wet. Otherwise, you may get
TN5A1634-E
electric shock or it may result in fire.
2-2 Maintenance
- Turn OFF the power when installing or removing the equipment. Otherwise, it may
cause shock, abnormal operation, or equipment failure.
- Periodic maintenance is recommended for continuous and safe use of this equip-
ment.
- Some parts installed on this equipment have a limited life and/or may deteriorate with
age.
2-3 Service life
- This product, excluding limited-life parts, is designed for a service life of 10 years
under general operating conditions.
- The warranty period for this unit (including accessories) is one year with appropriate
use.
2-4 Limited-life parts and consumable parts
This product contains the following limited-life parts and consumable parts which may
affect the service life of the product itself.
(1) Aluminum electrolytic capacitor
- Designed service life: 10 years under general working conditions
- Symptoms when a capacitor loses its capacity: deterioration of power quality, mal-
function
- Factors which affect capacitor life: temperature
The life is shortened by half when the temperature rises by 10°C. (Arrhenius' law)
- Replacement: Estimate the lifetime of capacitor according to your operating environ-
ment, and have the capacitor replaced or overhauled at appropriate time, at least
once in 10 years.
- 1 -
-10 to 50 degree C
90% RH or below (with no condensation)
30 min. or more
IEC61010-1: class II
IEC61010-1: degree 2
Power source
Loader communication
Functional insulation (AC1000V)
Ethernet communication
Functional insulation (AC500V)

Advertisement

loading

Summary of Contents for Fuji Electric PUMCE

  • Page 1 INP-TN1PUMCEa-E accidents such as abnormal voltage. (2) Regardless of the time period of the occurrence, Fuji Electric is not liable for the damage caused by the factors Fuji Electric is not responsible for, opportunity loss Thank you for purchasing the Fuji module type temperature controller.
  • Page 2 Do not use capacitors beyond its lifetime. Otherwise, electrolyte leakage or depletion - In order not to disturb heat dissipation, do not block the air vents on the top and bot- may cause odor, smoke, or fire. Please contact Fuji Electric or its service providers tom of the equipment.
  • Page 3 Setting - Communication behavior setting Set communication behavior by DIP switches on the back of the module (SW1 to SW6). SW No. Communication behavior (Note 1) (Note 1) Modbus/TCP bridge communication Modbus/TCP mapping communication Note 2 Micrex-SX programless communciation Note 1: You cannot set both SW2 and SW3 to ON simultaneously. Communication Note 2: When you set SW1 to ON, the Ethernet communication setting will be restored to factory default.
  • Page 4 3. After mounting modules to the DIN rails, push up all the locking tabs. Specification Modules are fastened to the DIN rails and to each other at the same time. 4. The power supplies are connected each other inside connected modules. General Specification Power Supply : 24V DC ±10%...