Sign In
Upload
Manuals
Brands
Fuji Electric Manuals
Temperature Controller
Micro-Controller X Socket type
Fuji Electric Micro-Controller X Socket type Manuals
Manuals and User Guides for Fuji Electric Micro-Controller X Socket type. We have
1
Fuji Electric Micro-Controller X Socket type manual available for free PDF download: Operation Manual
Fuji Electric Micro-Controller X Socket type Operation Manual (80 pages)
Digital temperature controller
Brand:
Fuji Electric
| Category:
Temperature Controller
| Size: 69.15 MB
Table of Contents
Safety Instructions
3
Warning
4
Installation and Wiring
4
Maintenance
5
Caution
6
Installation
6
Panel Mounting
6
Wiring
7
Operation
7
Others
7
Table of Contents
8
For Proper Use
10
Model Specifications
11
Part Names and Functions
12
1-1 Operation Keys
12
1-2 Indicators
13
1-3 Digital Characters
14
Basic Operation
15
Changing SV (Set Value)
16
2-3 Parameters List
17
Operation Mode
17
1St Block Parameter
17
2Nd Block Parameter
18
3Rd Block Parameter
20
Temperature Control Functions
21
Communication Function
21
Parameter Functions and Setting Procedure
22
1St Block Parameter
22
[MANU] Manual Mode Selection (001)
22
[Stby] Standby Setting (002)
23
[Prog] Ramp Soak Control (004)
24
[LACH] Alarm Latch Cancel (005)
26
[At] Auto-Tuning (006)
27
[Tm1] [Tm2] Timer 1 Display (007), Timer 2 Display (008)
29
[AL1] [A1-L] [A1-H] Alarm 1 Settings (010 , 011, 012)
30
[AL2] [A2-L] [A2-H] Alarm 2 Settings (013, 014, 015)
30
[Loc] Key Lock (019)
31
2Nd Block Parameter
32
[P] Proportional Band (030)
32
[I] Integral Time (031)
32
[D] Derivative Time (032)
32
[Hys] Hysteresis Range for ON/OFF Control (033)
34
[Bal] Output Convergence Value (036)
36
[AR] Anti-Reset Windup (037)
37
[Ctrl] Control Algorithm (038)
38
[Slfb] PV (Process Variable) Stable Range (039)
41
[Onof] Hysteresis Mode (040)
42
[Tc] Cycle Time of Control Output 1 (041)
43
[P-N2] Input Signal Code (043)
44
[P-SL] Lower Limit of Measuring Range (044)
45
[P-SU] Upper Limit of Measuring Range (045)
45
[P-Dp] Decimal Point Position (046)
47
[PVOF] PV Offset (048)
48
[SVOF] SV Shift (050)
49
[P-Df] Time Constant of Input Filter (050)
50
[ALM1] [ALM2] Alarm Type 1, 2 (051, 052)
51
[Stat] Status Display of Ramp Soak (054)
53
[Ptn] Ramp Soak Execution Pattern (055)
54
[SV-1] to [SV-8] 1St Target SV to 8Th Target SV (056 to 077)
55
[Tm1R] to [Tm8R] 1St Ramp Time to 8Th Ramp Time (057 to 078)
55
[Tm1S] to [Tm8S] 1St Soak Time to 8Th Soak Time (058 to 079)
55
[Mod] Ramp Soak Mode (080)
57
3Rd Block Parameter
59
[P-N1] Control Action (090)
59
[SV-L] SV (Set Value) Lower Limiter (091)
60
[SV-H] SV (Set Value) Upper Limiter (092)
60
Dly1 Dly2 Delay Time 1, 2 (093, 094)
61
A1Hy A2Hy Alarm 1, 2 Hysteresis (098, 099)
61
A1Op A2Op Alarm 1, 2 Options (101, 102)
63
[PLC1] [PHC1] OUT1 Upper/Lower Limits (104, 105)
64
[Pcut] Output Limit Types (108)
65
[Out1] Output Value (MV) Display (109)
66
[RCJ] RCJ (Cold Junction Compensation) Setting (111)
67
[Adj0] User-Definable Zero Adjustment (113)
68
[Adjs] User-Definable Span Adjustment (114)
68
Dsp1 to Dp14 Parameter Mask (126 to 139)
70
[Uky1] [Uky2] [Uky3] USER Key Assignment (143, 144, 145)
72
[Flo1] MV1 During FALT (146)
73
[Dspt] PV/SV Display off (148)
74
Troubleshooting
75
Advertisement
Advertisement
Related Products
Fuji Electric Micro-controller X Series
Fuji Electric Micro Control X Series
Fuji Electric Micro Control X
Fuji Electric MICREX-F Series
Fuji Electric MICREX-SX series
Fuji Electric micrex-sx SPH
Fuji Electric MICREX-F
Fuji Electric MICREX-SX series SPF
Fuji Electric MICREX-SX Series SPH
Fuji Electric MICREX-SX SPF
Fuji Electric Categories
Inverter
Measuring Instruments
Air Conditioner
Controller
Control Unit
More Fuji Electric Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL