[Mod] Ramp Soak Mode (080) - Fuji Electric Micro-Controller X Socket type Operation Manual

Digital temperature controller
Table of Contents

Advertisement

Mod Ramp soak mode (080)
[Description] –––––––––––––––––––––––––––––––––––––––––––––––––––––––
Allows you to set the method of ramp soak operation.
You can select from 16 options that are the combinations of the following four items.
Power-on start
END output
oFF output
Repeat
Setpoint
Power-on start
0
off
1
off
2
off
3
off
4
off
5
off
6
off
7
off
8
on
9
on
10
on
11
on
12
on
13
on
14
on
15
on
If the Repeat setting is off, the PXF retains the last SV after the ramp soak operation is over.
Starts ramp soak with the current PV when the PXF is turned on.
Maintains the same state as at the end of ramp soak when ramp soak is complete.
Switches to the OFF state when ramp soak is complete.
Repeats ramp soak from step 1 when the last step finishes.
Power on
SV-1
start
1st soak
PV
1st ramp
tM1R
tM1S tM2R tM2S
End output
Maintain control
Maintain control
Maintain control
Maintain control
Standby Mode
Standby Mode
Standby Mode
Standby Mode
Maintain control
Maintain control
Maintain control
Maintain control
Standby Mode
Standby Mode
Standby Mode
Standby Mode
Repeat on
SV-2
2nd soak
SV-3
3rd ramp
4th ramp
3rd soak
2nd ramp
tM3R
tM3S
tM4R tM4S
oFF output
Maintain control
Maintain control
Standby Mode
Standby Mode
Maintain control
Maintain control
Standby Mode
Standby Mode
Maintain control
Maintain control
Standby Mode
Standby Mode
Maintain control
Maintain control
Standby Mode
Standby Mode
55
2nd block parameter
SV-4
4th soak
Repeat
off
on
off
on
off
on
off
on
off
on
off
on
off
on
off
on