Pilz PMC Series Installation Manual page 39

Motion control
Table of Contents

Advertisement

8 Installation
8.4.5.2
Technical data for connecting cables
Further information on the chemical, mechanical and electrical characteristics of the cables can
be obtained from our customer service.
Observe the rules in the section "Conductor cross-sections" on page 22. To reach the
max. permitted cable length, you must use cable material that matches the capacitance
requirements listed below.
8.4.5.3
Insulation material
Sheating
Core insulation
8.4.5.4
Capacitance
Motor cable
Resolver-/Encoder cable less than 120 pF/m
8.4.5.5
Technical data
The brackets in the core definition indicate the shielding.
All cables are suitable for use as trailing cables.
The technical data refer to use as moveable cables.
Operating life : 1 million bending cycles
Cores
[mm²]
(4x1.0)
(4x1.5)
(4x1.0+(2x0.75))
(4x1.5+(2x0.75))
(4x(2x0.25))
(7x(2x0.25))
* North America supplies cables up to 39 meters
* Europe supplies cables up to max. length
Motor cables longer than 25m only with motor choke.
You can order a special motor choke from us.
Installation manual for PMC tendo DD5/PMCprimo Drive3
PUR (polyurethane, code 11Y)
PETP (polyesteraphtalate, code 12Y)
less than 150 pF/m
max.
Use for
length
[m]
50*
motor
power
50*
motor
power
50*
motor incl.
brake
50*
motor incl.
brake
100*
Resolver
50*
Encoder
Operating-
Outside
temp. range
diameter
[°C]
[mm]
-30 / +80
10
-30 / +80
10.5
-30 / +80
10.5
-30 / +80
11.5
-30 / +80
7.7
-30 / +80
9.9
Bending
radius
[mm]
100
105
105
120
70
90
Page 39