9.7
Digital and analog inputs and outputs
9.7.1
Analog inputs (X3)
The servo amplifier is fitted with two programmable differential inputs for analog setpoints.
AGND (X3/7) must always be joined to the GND of the controls as a ground reference.
9.7.1.1
Technical characteristics
•
Differential input voltage max. ± 10 V
•
Ground reference AGND, terminal X3/7
•
Input resistance 10 kΩ
•
Common-mode voltage range for both inputs ± 10 V
•
Update rate: 62,5 µs
Page 56
Installation manual for PMCtendo DD5/PMCprimo Drive3
9 Interfaces