10.6

Error messages PMCtendo DD5

Any errors that occur are shown in coded form by an error number in the LED display on the
front panel. All error messages result in the BTB/RTO contact being opened, and the output
stage of the amplifier being switched off (motor loses all torque), and the motor-holding brake is
activated. Detailled description see "ASCII command reference".
Number Designation
E/S/A/P status Messages
. . .
-
F01*
F02*
F03*
F04
F05*
F06
F07
F08*
F09
F10
F11
F12
F13*
F14
F15
F16*
F17
F18
F19*
F20
F21
F22
F23
F24
F25
F26
F27
F28
F29
F30
F31
F32
* = these error messages can be cleared without a reset, by using the ASCII command
CLRFAULT. If only one of these errors is present and the RESET button or the I/O RESET
function is used, only the CLRFAULT command will be executed.
You can find further information on handling errors from page 113 and in the "ASCII
command reference" (part of the setup software's online help system)
Page 98
Explanation
status messages, no error, see p. 94
status Message
amplifier is updating the startup configuration
status Message
status message, no error, programming mode
heat sink temperature
heat sink temperature too highlimit is set by manufacturer to
80°
overvoltage
overvoltage in DC bus linklimit depends on the electrical
supply voltage
following error
message from the position controller
feedback
cable break, short-circuit, short to ground
undervoltage
undervoltage in DC bus linklimit is set by manufacturer to
100V
motor temperature
motor temperature too high or temp. sensor defect
reserved
reserved
overspeed
motor runs away, speed is too high
EEPROM
checksum error
signal failure X5
signal failure X5 (cable break or similar)
brake
cable break, short-circuit, short to ground
motor phase
motor phase missing (cable break or similar)
ambient temperature
ambient temperature too high
output stage
fault in the power output stage
I²t max.
I²t maximum value exceeded
mains BTB/RTO
2 or 3 phases missing in the mains supply feed
A/D converter
error in the analog-digital conversion, normally caused by
extreme electromagnetic interference
regen
regen circuit faulty or incorrect setting
DC bus link
DC bus link breakdown
slot error
slot error, depends on the type of expansion card (see ASCII
command reference)
handling error
Handling error on the expansion card
reserved
reserved
CAN-bus off
severe CAN bus communication error
warning
warning is displayed as fault
commutation error
commutation error
limit switch
hardware limit switch error on homing move
AS
operational error with -AS- , input for AS-Enable and
ENABLE have been set at the same time
fieldbus error
fieldbus error (see ASCII command reference)
fieldbus error
fieldbus communication is disturbed (see ASCII command
reference)
emergency timeout
Timeout emergency stop
reserve
reserve
system error
system software not responding correctly