Advertisement

Quick Links

PITestop
}
Control and signal devices
Operating Manual-21136-EN-11

Advertisement

Table of Contents
loading

Summary of Contents for Pilz PITestop

  • Page 1 PITestop Control and signal devices Operating Manual-21136-EN-11...
  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    Safety assessment Use of qualified personnel Warranty and liability Disposal For your safety Unit features Function description Modules Installation Preparing for operation Dimensions Technical details Safety characteristic data Order reference Product Accessories EC declaration of conformity Operating Manual PITestop 21136-EN-11...
  • Page 4: Introduction

    PITestop Introduction Validity of documentation This documentation is valid for the product PITestop. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5: Safety

    Safety Intended use The device PITestop is intended for use in safety circuits in accordance with IEC/ EN 60947-5-1, IEC/EN 60947-5-5, EN 60204-1, EN ISO 13849-1. Before using the device, a safety assessment of the overall system must be performed in accordance with the Ma- chinery Directive.
  • Page 6: Warranty And Liability

    Features: Panel mount version or surface mount version with two-part enclosure (box) Turn in either direction to release or turn right for key-release various actuators – Standard actuator – Actuator with key-release Operating Manual PITestop 21136-EN-11...
  • Page 7: Function Description

    PIT MHR5 (5 slots) NOTICE The illuminating contact block for the illuminated actuator requires one slot. Contact block sets, pre-assembled with bracket: PIT es safe contact block for panel mount version – PIT esb1 (1 N/C / N/O contact*) Operating Manual PITestop 21136-EN-11...
  • Page 8: Installation

    Attach "illuminating contact block" to the contact block bracket – Feed the cable through an opening in the panel (see Opening in the panel in the panel mount version [ 10]) and attach to the actuator Operating Manual PITestop 21136-EN-11...
  • Page 9 10]) After connecting the wiring to the contact block, screw the upper part of the surface mount housing with actuator and contact block to the lower part of the enclosure Fig.: Installing PITestop Legend [1] Actuator [2] Upper part of the surface mount housing...
  • Page 10 PITestop only with illuminated actuators Fig.: Opening in the panel in the panel mount version Fig.: Attachment of the enclosure for a surface mount version Operating Manual PITestop 21136-EN-11...
  • Page 11: Preparing For Operation

    The slides of the outer contact blocks must be pointing in- wards, so that all of the slides are within the ring when the bracket is at- tached (see drawing below). Fig.: Attachment of the enclosure Operating Manual PITestop 21136-EN-11...
  • Page 12 PIT esb2.2 PIT esb2.3 PIT esb2.4 PIT es2.13 *The contacts are closed when the actuator is snapped in place NOTICE Contact block sets PIT esb1.2, PIT esb1.4 and PIT esb2.3 cannot be used with an illuminated actuator! Operating Manual PITestop 21136-EN-11...
  • Page 13: Dimensions

    PITestop Dimensions Standard actuator (PIT es2.11) 55,00 31,50 Actuator with key-release (PIT es2.12) 55,00 31,50 Operating Manual PITestop 21136-EN-11...
  • Page 14 PITestop Actuator with illumination (PIT es2.13) Cable approx. 10 cm black Actuator with key-release and protective collar (PIT es5.12) 67,00 31,55 Operating Manual PITestop 21136-EN-11...
  • Page 15 PITestop Surface mount version with standard actuator (PIT es2.11) 55,00 31,50 27,00 37,00 39,00 19,50 Operating Manual PITestop 21136-EN-11...
  • Page 16 PITestop Panel mount version with standard actuator (PIT es2.11) 55,00 31,50 27,00 45,30 37,00 Opening(s) in the panel Drawing on the right: only for illuminated actuators PIT es2.13 Operating Manual PITestop 21136-EN-11...
  • Page 17: Technical Details

    Where standards are undated, the 2016-05 latest editions shall apply. Order no. 400520 – 400521 General 400520 400521 Approvals TÜV, cULus Listed TÜV, cULus Listed Self-monitored Electrical data 400520 400521 Min. contact current 1 mA 1 mA Operating Manual PITestop 21136-EN-11...
  • Page 18: Safety Characteristic Data

    You must comply with the safety-related characteristic data in order to achieve the required safety level for your plant/machine. Safety characteristic data B10d in accordance with EN ISO 13849-1:2015 181.500 and EN 62061 Lambda /Lambda in accordance with EN 62061 0,20 Operating Manual PITestop 21136-EN-11...
  • Page 19: Order Reference

    Standard actuator, black 400 110 PIT es2.12 Actuator with key-release, black 400 111 PIT es2.13 Illuminated actuator, black 400 112 PIT es5.12 Actuator with key-release and protective collar, red, no Pilz inscrip- 400 601 tion on the actuator Operating Manual PITestop 21136-EN-11...
  • Page 20: Accessories

    This product/these products meet the requirements of the directive 2006/42/EC for ma- chinery of the European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost- fildern, Germany Operating Manual PITestop...
  • Page 21 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95600621 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30...

Table of Contents