Sine Encoder Without Data Channel (X1) - Pilz PMC Series Installation Manual

Motion control
Table of Contents

Advertisement

9 Interfaces
9.6.7

Sine Encoder without data channel (X1)

An sine-cosine encoder without data channel can be used as standard motor feedback. Select
feedback type 7 "SinCos 5V with W&S". Drive executes wake&shake to calculate the necessary
start-up information for the position controller every time the 24V auxiliary voltage is switched
on.
The thermostat contact in the motor is connected via the encoder cable to X1 and evaluated
there.
If lead lengths of more than 50m are planned, please consult our customer service.
Frequency limit: 350 kHz
Don't use this feedback type with vertical load (hanging load).
Installation manual for PMC tendo DD5/PMCprimo Drive3