9 Interfaces
9.7.5
Digital outputs (X10)
These outputs are available only at a PMCprimo Drive3!
All digital outputs are electrically isolated through optocouplers.
9.7.5.1
Technical characteristics
•
Reference ground is EGND (terminal X10, pin 2)
•
All digital outputs are overload- and shortcircuit protected
•
„High side" outputs: 24V /0,1 A each output
9.7.5.2
Application example
The digital outputs can be used for CAM functions or timer outputs. More information can be
found in the PMCprimo programming manual.
Installation manual for PMC tendo DD5/PMCprimo Drive3
Page 63