Master-Slave Operation, Encoder Master Control; Connection To A Pmctendo Dd5 Master, 5V Signal Level (X5) - Pilz PMC Series Installation Manual

Motion control
Table of Contents

Advertisement

9.9

Master-slave operation, encoder master control

These function is available only at a PMCtendo DD5!
This interface can be used to link several amplifiers together in master-slave operation.
Parameter setting for the slave amplifier is carried out with the aid of the setup software
(electrical gearing). The resolution (no. of pulses/turn) can be adjusted, and the analog setpoint
inputs are out of action.
9.9.1.1
Signal diagram (for encoders with RS422 or 24V output)
9.9.2

Connection to a PMCtendo DD5 master, 5V signal level (X5)

This interface can be used to link several amplifiers together in master-slave operation. Up to
16 slave amplifiers can be controlled by the master, via the encoder output. The SubD
connector X5 is used for this purpose.
Frequency limit: 1.5 MHz, transition time tv ≤ 0.1µs